PerformancePro Cascade Series Owner's Manual

High rpm pumps

Advertisement

Quick Links

PUMP MODEL: ________________________
SERIAL #: ____________________________
DATE PURCHASED: ___________________
Retain this information for future reference.
For questions regarding installation, operation or maintenance
5976 SE Alexander St., Ste F, Hillsboro, OR 97123
P (503) 356-5888 F (503) 356-1660 E sales@performancepropumps.com
WWW.PERFORMANCEPROPUMPS.COM
call (503) 356-5888
OWNER'S MANUAL
CASCADE
HIGH RPM PUMPS

Advertisement

Table of Contents
loading

Summary of Contents for PerformancePro Cascade Series

  • Page 1 OWNER’S MANUAL CASCADE HIGH RPM PUMPS PUMP MODEL: ________________________ SERIAL #: ____________________________ DATE PURCHASED: ___________________ Retain this information for future reference. For questions regarding installation, operation or maintenance call (503) 356-5888 5976 SE Alexander St., Ste F, Hillsboro, OR 97123 P (503) 356-5888 F (503) 356-1660 E sales@performancepropumps.com WWW.PERFORMANCEPROPUMPS.COM...
  • Page 2: Important Safety Instructions

    Important Safety Instructions Please read all instructions completely before installing or operating the pump. Save this manual for future reference regarding installation, operation, maintenance and troubleshooting of this pump. Please note the safety warning symbols as noted below: This warning symbol indicates the potential for personal injury or damage to the pump! Please be cautious! This symbol indicates a hazard which if not avoided could result WARNING...
  • Page 3 In installation applications where no swing check valve is installed, it is important to install a priming pot to facilitate priming. The Cascade series is designed to operate as gravity fed or with a swing check valve and priming pot installed. Without any of these factors in place, the system will not function properly. If working with an installed priming pot, the lid should be removed, priming pot lled with water, lid replaced ensuring all ttings are tight and sealed with PTFE paste or similar sealant.
  • Page 4 Ensure the vault is properly ventilated. 6. The Cascade series pump ports are 1.5” NPT on both the inlet and discharge ports. The 1.5” NPT ports may be connected with ttings available from PerformancePro Pumps (MPF-215) or standard 1.5” NPT PVC ttings available at your local hardware store and should be connected to PVC or ex pipe plumbing.
  • Page 5: Installation

    10. Fill the pump housing and supply lines with water. Turn the motor on by plugging in the unit or switching on the power supply. Priming should be immediate as Cascade series pumps should be primed at initial start up. However, with a priming pot attached full prime time may vary in length. See page 3 for details.
  • Page 6 Electrical Before wiring any part of the motor be sure the power is disconnected. It is recommended that wiring be performed be a licensed electrician or professional service person. WARNING If pump has a factory preinstalled cord, wiring has already been set and this step is not needed; unless voltage change is required in which case the cord will need to be removed and steps followed below.
  • Page 7: Maintenance

    3. If you are mechanically minded, the option to order bearings and a seal kit from PerformancePro Pumps or your local dealer is available for you to perform the repair.
  • Page 8: Pump Disassembly

    Pump Disassembly Tools required: 1. (2) 7/16” wrenches (for 2- ” bolts) 2. Large at blade screwdriver 3. Small at blade screwdriver 4. 9/16” open end wrench (for 1” bolts) 1” HEX BOLT MECHANICAL SEAL VOLUTE VOLUTE O-RING DRAIN PLUG MOTOR WITH ORING SLINGER...
  • Page 9 If the pump has been running with low incoming water ow for more than three (3) minutes, shut the system o immediately and check ttings for air leaks. Full ow with installed check valve should be obtained at initial start up. Call PerformancePro Pumps for additional technical assistance. WARNING * Handle the mechanical seal with care to protect the polished and lapped faces of the seal from damage.
  • Page 10 Winterization Winterizing your pump is necessary if freezing temperatures occur in your geographic area for extended periods of time. If freezing tempuratures are not common but may on occassion drop below freezing, it is advised to follow winterization procedure to protect your pump. Freezing tempuratures cause water to expand and may result in damage to the pump, plumbing, and other connected components resulting in costly repairs.
  • Page 11: Troubleshooting

    Troubleshooting The following troubleshooting tips support the most common issues. For additional assistance, please contact techhelp@performancepropumps.com or 503-356-5888. PROBLEM KNOWN ISSUE TRY THIS Pump is not priming No water in strainer pot Fill strainer pot with water and close lid. if installed Ensure plumbing valves are open.
  • Page 12 Parts 1” HEX BOLT MECHANICAL SEAL VOLUTE VOLUTE O-RING DRAIN PLUG MOTOR WITH ORING SLINGER DRAIN PLUG BRACKET WITH ORING BORE O-RING BRACKET IMPELLER HEX BOLT 3/4” DESCRIPTION PART NUMBER ITEM BEARING-03 Bearing Motor Bearings-03 Bracket Bracket (Rear Housing in Noryl) PNB-10 PPB-10 Bracket (Rear Housing in Polypropylene)
  • Page 13: Performance Data

    Performance Data...
  • Page 14: Warranty

    In the event this product malfunctions within three years (for fresh water use) or one year (for use with salt water or other suitable fluids) from the date of purchase the sole obligation of PerformancePro Pumps will be to replace or make this product capable of being operated according to the original product description without charges for labor or parts to the Purchaser, and are subject to the following conditions: 1.
  • Page 15: Protect Your Investment

    Protect your pump motor from the elements today! * Excellent weather protection * Noise abatement * Easy to assemble * Customizable precut knockout sections * Sturdy construction * Fits Artesian, Artesian 2, ArtesianPro and Cascade series 15” 15” 14” Part #: MPC-10...

Table of Contents