PerformancePro ARTESIAN 2 Owner's Manual

PerformancePro ARTESIAN 2 Owner's Manual

Low rpm pumps

Advertisement

Quick Links

PUMP MODEL: ________________________
SERIAL #: ____________________________
DATE PURCHASED: ___________________
Retain this information for future reference.
For questions regarding installation, operation or maintenance
5976 SE Alexander St., Ste F, Hillsboro, OR 97123
P (503) 356-5888 F (503) 356-1660 E sales@performancepropumps.com
WWW.PERFORMANCEPROPUMPS.COM
call (503) 356-5888
OWNER'S MANUAL
ARTESIAN 2
LOW RPM PUMPS

Advertisement

Table of Contents
loading

Summary of Contents for PerformancePro ARTESIAN 2

  • Page 1 OWNER’S MANUAL ARTESIAN 2 LOW RPM PUMPS PUMP MODEL: ________________________ SERIAL #: ____________________________ DATE PURCHASED: ___________________ Retain this information for future reference. For questions regarding installation, operation or maintenance call (503) 356-5888 5976 SE Alexander St., Ste F, Hillsboro, OR 97123 P (503) 356-5888 F (503) 356-1660 E sales@performancepropumps.com...
  • Page 2: Important Safety Instructions

    Important Safety Instructions Please read all instructions completely before you installing or operating the pump. Save this manual for future reference regarding installation, operation, maintenance and troubleshooting of this pump. Please note the safety warning symbols as noted below: This warning symbol indicates the potential for personal injury or damage to the pump! Please be cautious! This symbol indicates a hazard which if not avoided could result WARNING...
  • Page 3 The Prime The Artesian 2 Low RPM pump is considered a “true” self-priming pump. This means it is designed to prime and operate at varying heights up to 9 feet above the water source surface as well as varying horizontal lengths.
  • Page 4 General Before Installation Open the pump box when received and inspect for evidence of rough handling or damage to the pump and verify the product ordered. If damage is found, notify the freight carrier and contact the vendor purchased from immediately. For order discrepancies, contact the vendor purchased from immediately.
  • Page 5: Installation

    Installation 1. After thorough inspection, carefully remove the pump from the box. 2. Secure the pump on a solid, at foundation. A covered location is always best and care should be taken to ensure adequate ventilation. See installation tips for bene cial tips. 3.
  • Page 6 Electrical Before wiring any part of the motor be sure the power is disconnected. It is recommended that wiring be performed by a licensed electrician or professional serviceperson. WARNING If pump has a factory preinstalled cord, wiring has already been set and this step is not needed; unless voltage change is required in which case the cord will need to be removed and steps followed below.
  • Page 7 2. Contact PerformancePro Pumps for a list of authorized motor repair centers near you. Note that this option may not honor any warranty but may provide a good alternative. 3. If you are mechanically minded, the option to order bearings and a seal kit from PerformancePro Pumps is available to perform the repair.
  • Page 8: Pump Disassembly

    Pump Disassembly All moving parts are located in the rear sub-assembly of this pump. Tools required: 1. 3/32 inch Allen wrench 2. 7/16 inch open end wrench 3. 9/16 inch open end wrench 4. Small and large athead screwdrivers 5. #3 Phillips screw driver Rear Sub-assembly Clamp Ring Union...
  • Page 9 Monitor water level in the volute/basket area to ensure water is always present. If the pump has been running with no incoming water ow for more than 15 minutes, shut the system o immediately and call PerformancePro Pumps for technical assistance. WARNING * Handle the mechanical seal with care to protect the polished and lapped faces of the seal from damage.
  • Page 10 Winterization Winterizing your pump is necessary if freezing temperatures occur in your geographic area for extended periods of time. If freezing tempuratures are not common but may on occassion drop below freezing, it is advised to follow winterization procedure to protect your pump. Freezing tempuratures cause water to expand and may result in damage to the pump, plumbing, and other connected components resulting in costly repairs.
  • Page 11: Troubleshooting

    Troubleshooting The following troubleshooting tips support the most common issues. For additional assistance, please contact techhelp@performancepropumps.com or 503-356-5888. PROBLEM KNOWN ISSUE TRY THIS Pump is not priming No water in strainer pot Fill strainer pot with water and close lid. Ensure plumbing valves are open.
  • Page 12 Parts Clamp Ring Union Hex Bolts (6) 1 1/8” Assembly Hex Bolts (4) 7/8” Bracket o-ring Motor Basket Tailpiece Mechanical Tailpiece Lid o-ring Seal o-ring Union Assembly Impeller Bracket o-ring Bracket Bore Motor Base Drain plug o-ring & o-ring Volute ITEM DESCRIPTION PART NUMBER...
  • Page 13 Parts ITEM PART NUMBER DESCRIPTION Impeller Set Screw ASI-09 Impeller reverse set screw with gasket (3450 RPM only) ALL-40 Clear Lexan™ Lid ABL-30 Lid O-Ring O-Ring for Lexan™ Lid APF-3-10 Motor Base Plastic Motor Base Quick Clamp APC-50 Quick clamp for Volute Seal - Mechanical MPS-513 316 Stainless Steel Carbon vs.
  • Page 14: Performance Data

    Performance Data...
  • Page 15: Warranty

    In the event this product malfunctions within three years (for fresh water use) or one year (for use with salt water or other suitable fluids) from the date of purchase the sole obligation of PerformancePro Pumps will be to replace or make this product capable of being operated according to the original product description without charges for labor or parts to the Purchaser, and are subject to the following conditions: 1.
  • Page 16: Protect Your Investment

    Protect your pump motor from the elements today! * Excellent weather protection * Noise abatement * Easy to assemble * Customizable precut knockout sections * Sturdy construction * Fits Artesian, Artesian 2, ArtesianPro and Cascade series 15” 15” 14” Part #: MPC-10...

Table of Contents