Setting The Next Event Number [Next Event No]; Setting The Power Off Time Of The Tc Card [Tc Power Timer] - Fostex FR-2 Owner's Manual

Tc card for the fr-2 field memory recorder
Hide thumbs Also See for FR-2:
Table of Contents

Advertisement

The "Next Event No" menu item sets the event number which is given to an audio file when you start
recording a new file. By default, the event number is set to "00000", and the first audio file recorded
has event number "00001". The event number is counted up each time you make recording.
<Note>: The event number is recorded to each file as "fEVENT" information in the BWF BEXT
Chunk Description.
After bringing up the third page of the TC Setup menu, use the [MENU] dial to select "Next
Event No" and press the [ENTER] key. The rightmost digit of the current event number (by
default, "00000") starts flashing and you can now set the desired event number.
Use the [MENU] dial to enter a desired number and press the [ENTER] key to confirm the
setting. You can set the event number between 00000 and 99999. Select the "Next event No"
menu item and press the [ENTER/YES] key. The next event number setting starts flashing and
you can now edit the number.

Setting the power off time of the TC card [TC Power Timer]

The "TC Power Timer" menu item set the automatic power off time of the TC card after turning off the
FR-2 power. By default, it is set to "5min", so the TC card is turned off five minutes after the FR-2 is
turned off.
After bringing up the third page of the TC Setup menu, use the [MENU] dial to select "TC Power
Timer" and press the [ENTER] key. The current setting (by default, "5min") starts flashing and
you can now select a desired option.
Use the [MENU] dial to select a desired option and press the [ENTER] key to confirm the selec-
tion. You can select from among the following options. During the time from when the FR-2 is
turned off until when the TC card is turned off, [GEN] indicator flashes.
0min
5min
10min
15min
30min
1hour
2hour
4hour
8hour
Cont. (Continue)
* The power consumption of the TC card is approximately 200 mW.

Setting the next event number [Next Event No]

The TC card is turned off immediately after the FR-2 is turned off.
The TC card is turned off five minutes after the FR-2 is turned off.
The TC card is turned off ten minutes after the FR-2 is turned off.
The TC card is turned off 15 minutes after the FR-2 is turned off.
The TC card is turned off 30 minutes after the FR-2 is turned off.
The TC card is turned off one hour after the FR-2 is turned off.
The TC card is turned off two hours after the FR-2 is turned off.
The TC card is turned off four hours after the FR-2 is turned off.
The TC card is turned off eight hours after the FR-2 is turned off.
The TC card is not turned off even if the FR-2 is turned off.