    CONTENT 2. SYMBOLS AND MARKING 3. SAFETY INSTRUCTIONS AND PRECAUTIONS 4. DIMENSIONS AND WEIGHT 5. ELECTRICAL DATA 6. CONSTRUCTION 7. OPERATING CONDITIONS PACKAGE 9. TRANSPORTATION 10. UNPACKING 11. STANDART PACKAGE OF COMPONENTS 12. PLACE REQUIREMENTS 13. MOUNTING 14. CONNECTION OF THE AIR DUCT 15.
  • Page 3: Symbols And Marking

    2. SYMBOLS AND MARKING LN: XX000000 2019.01.01 Figure. 2.1. Technical label 1 - Logo; 2 - Product code (SKU); 3 - Product name; 4 - Technical data; 5 - Production place; 6 - Lot number and production date; 7 - Serial number.
  • Page 4: Dimensions And Weight

    In exceptional cases harmful gases could be drawn out of the chimney or extraction ducting back into the room. In this case we strictly recommend to turn off Salda Antifrost and use an external preheater for heat exchanger anti-frost protection (see Salda Antifrost function on the Remote controller manual).
  • Page 5: Construction

    phase/voltage [50 Hz/VAC] power/current [kW/A] 0,085 / 0,75 0,085 / 0,75 0,085 / 0,75 0,085 / 0,75 exhaust speed [min 3200 3200 3200 3200 Fans power/current [kW/A] 0,085 / 0,75 0,085 / 0,75 0,085 / 0,75 0,085 / 0,75 supply speed [min 3200...
  • Page 6: Operating Conditions

    7. OPERATING CONDITIONS +40 C +5 C +40 C +40 C -23 C +15 C 8. PACKAGE +40 C +5 C +40 C +40 C +40 C -40 C -3 C +15 C QUANTITY ON THE PALLET +40 C RIRS V EKO 3.0 [mm] [mm] [mm]...
  • Page 7: Unpacking

    10. UNPACKING Accessories may be packed together with the product. Prior to transporting the unit, first unpack the accessories. • Remove the film from the unit. • Remove the bracing packaging tape which keeps the protective profiles. • Remove the protective profiles. •After unpacking the unit, examine it to make sure that it it has not been damaged during transportation.
  • Page 8: Connection Of The Air Duct

    14. CONNECTION OF THE AIR DUCT D2 dimensions depend on unit. 15. CONNECTION DIAGRAM * KE1 - used in electrical version. In horizontal version heater is positioned before supply fan; * KV1 - used in water version. For more informa- tion please, check the manual.
  • Page 9: Connection Of The Unit To Electric Network

    Fireplace protection Alarm indication output System mode switch (START/STOP) Fans speed switch (BOOST) * Component/posibility to connect it depends on model. For more information please, check the manual 16. CONNECTION OF THE UNIT TO ELECTRIC NETWORK • Supply voltage to the unit must be connected by a qualified specialist following the manufacturer’s instructions and effective safety instructions. •...
  • Page 10: Fan

    18.2. FAN - Maintenance and repair should only be performed by experienced and trained staff. - The fan should be inspected and cleaned if needed at least once a year. - Be sure the fan is disconnected from power source before performing any maintenance or repair. - Proceed to maintenance and repair after any rotation in the fan stopped.
  • Page 11: Automatic Control

    19. AUTOMATIC CONTROL Supply air temperature can be adjusted according to the temperature measured by the supply or extracted air temperature sensor and the tem- perature which is set by the user on the remote control panel. User selected supply air temperature is maintained by the plate (or rotor) heat exchanger and additional electric and/or water heater (optional).
  • Page 12: System Protection

    Also, CO (extract air) converter can be connected (if no pressure converters are connected). 19.1. SYSTEM PROTECTION a) Several steps of protection are provided for protection of the water heater. First: if during cold periods the temperature of the outward water flow drops below +10 °C (as measured by the TV sensor), then the water heater valve actuator M6 is forced to open regardless the need for heat.
  • Page 13: Modbus Adresses

    Figure 19.2.2. Microswitches 1 and 2 19.3. MODBUS ADRESSES Data Quan- Name ModBus func. tity of Description Values dress data 1 - a c t i v e , Antifrost 01h_Read_Coils Plate heat exchanger frost protection function o-passive 1 - a c t i v e , Fire 01h_Read_Coils Fire alarm...
  • Page 14: Electrical Connection Of The Hvac Unit

    ToutDoor 04h_Read_Input Ouside air temperature sensor value Hex: FFEC Twater 04h_Read_Input Return water temperature sensor value Hex: FFEC 19.4. ELECTRICAL CONNECTION OF THE HVAC UNIT Electrical connection can only be implemented by the qualified electrician in accordance with the applicable international and national electrical safety requirements and requirements for installation of electrical devices.
  • Page 15: Control Board Rg1

    Air temperature sensors and air quality converters. Supply air temperature sensors and air quality converters (if additionally used) must be mounted as far as possible from the ventilation devices (within the confines of sensor cable) up to the first branch or turn of the air transportation system.
  • Page 16: Labeling, Characteristics Of The Controller And The System Components

    20.1. LABELING, CHARACTERISTICS OF THE CONTROLLER AND THE SYSTEM COMPONENTS Contact Labeling Description Max. load Min. load type [ A ] [ mA ] L(230V/50Hz power supply) N(230V/50Hz power supply) Electric heater | EN RIRS 400-700 V EKO 3.0 v2019.06...
  • Page 17 Electric preheater/rotor ON/OFF 230V/50Hz Voltage of Normal speed for air fans Voltage of Min speed for air fans Extract room(s) air fan. Power to exaust air fan IV 4.2A Supply air fan. Power to supply air fan PV 4.2A PUMP Pump motor ON/OFF 230V/50Hz Water heater...
  • Page 18: Regular System Check-Up

    Fans guard Extract air temperature sensor Temp. and humidity sensor for extract air. Extract air humidyti sensor Supply air temperature sensor Supply air temperature sen- sor. Exhaust air temperature sensor Exhaust air temperature sen- Supply air fan 0-10V Supply air fan. Extract air fan 0-10V Extract room(s) air fan.
  • Page 19: Electrical Connection Diagram

    21. ELECTRICAL CONNECTION DIAGRAM 21.1. RIRS 400 VE EKO 3.0 PE N RIRS 400-700 V EKO 3.0 v2019.06 EN |...
  • Page 20: Rirs 400 Vw Eko

    21.2. RIRS 400 VW EKO 3.0 PE N | EN RIRS 400-700 V EKO 3.0 v2019.06...
  • Page 21: Rirs 700 Ve Eko

    21.3. RIRS 700 VE EKO 3.0 RIRS 400-700 V EKO 3.0 v2019.06 EN |...
  • Page 22: Rirs 700 Vw Eko

    21.4. RIRS 700 VW EKO 3.0 PE N | EN RIRS 400-700 V EKO 3.0 v2019.06...
  • Page 23: Ecodesign Data Table

    [ kWh/a ] 1910 1910 1910 1910 ErP Compliance 2018 2018 2018 2018 Internet address for disassembly instructions www.salda lt 700 VER 700 VEL 700 VWR 700 VWL RIRS EKO 3.0 Specific energy consumption (SEC) cold [ kWh/m a ] -74,1 -74,1...
  • Page 24 AHS Warm [ kWh/a ] 1885 1885 1885 1885 ErP Compliance 2018 2018 2018 2018 Internet address for disassembly instructions www.salda lt | EN RIRS 400-700 V EKO 3.0 v2019.06...
  • Page 25: Declaration Of Confimity

    Should any alterations be made in the products, this declaration will no longer apply. Notified body: VšĮ Technikos priežiūros tarnyba, Naugarduko g. 41, LT – 03227 Vilnius, Lithuania, identification number 1399. Quality: Salda UAB activities are in line with the international quality management system standard ISO 9001:2015. Date...
  • Page 26: Warranty

    3.4. when the unit was used not for its original purpose. 3.5. Company SALDA UAB is not responsible for potential loss of property or personal injury in cases where AHU is manufactured without a control system and the control system will be installed by the client or third parties. The manufacturer’s warranty does not cover devices that will be damaged by installing the control system.
  • Page 27 RIRS 400-700 V EKO 3.0 v2019.06...
  • Page 28 Heat exchanger cleaning Every 3-4 Filter replacement months** Look at the product label. ** - At least. NOTE. The purchaser is required to fill in the “Product maintenance table”. MAN000124 MAN000124 Ragainės g. 100 +370 41 540 415 Šiauliai LT-78109, LITHUANIA office@salda.lt...

Table of Contents