Mast3Rpur Tm (If Equipped) - Master Spas MP Swim Spa Owner's Manual

Table of Contents

Advertisement

MAST3RPUR
NOTE: This regular maintenance for the Mast3rPur
the swim spa. Your Master Spas dealer or service organization can be contacted to schedule this
maintenance.
WARNING –
BEFORE PERFORMING ANY MAINTENANCE ON THE MAST3RPUR
SURE THE SWIM SPA IS SHUT DOWN.
UV LAMP REMOVAL
If the Green Power Indicator is on, but the Blue UV Lamp Indicator is off, the UV lamp needs to
be replaced. For maximum UV sanitation effect, replace the UV Lamp every 18 months. Refer to
Figure 2.
1.
Make sure the unit is disconnected from power and the lamp has cooled before starting
maintenance.
2.
Open the Spa Solar Eclipse by removing the two Enclosure Screws on the Upper Enclosure
Assembly and lifting it from the Enclosure Base.
3.
Disconnect the Lamp Connector attached to the lamp wires and place the Upper Enclosure
Assembly in a safe place.
4.
Gently pull the Lamp Wires till the top of the UV Lamp is out of the Lamp Retainer. Grasp
the white ceramic end of the UV Lamp and pull until it is fully removed. IF YOU ARE NOT
REPLACING THE LAMP, DO NOT TOUCH THE UV LAMP GLASS WITH YOUR BARE HANDS. The
oils on your hands can cause hot spots on the lamp and shorten its life. If oil from your
fingers is left on the lamp glass, clean it off with a soft towel and rubbing alcohol. If you are
removing an old lamp for replacement, handle the lamp carefully and dispose properly (see
Environmental Notice).
5.
Set the UV Lamp aside in a safe place.
DO NOT DIVE.
DO NOT DIVE.
TM
(IF EQUIPPED)
Figure 2: Spa Solar Eclipse Exploded View
system is not covered under the warranty of
TM
105
23
SYSTEM, MAKE
TM

Advertisement

Table of Contents
loading

Table of Contents