Options Sequential Thermostatic Single Lever Mixer Valve with Exposed and Concealed Fitting Options Fitting Instructions IMPORTANT! This Step-by-Step guide should be retained after installation.
Page 2
1. INTRODUCTION This booklet contains all the necessary fitting and water temperatures above 80˚C. This mixer valve is operating instructions for your MX Thermostatic bar also suitable for thermal storage, unvented systems mixer valve. and pumped gravity systems. Please read these instructions carefully. Read...
3. PACK CONTENTS Please make sure ALL components are included before starting the installation. Description Quantity Single Lever Mixer Valve Concealing Plate Dogleg Thread Adaptors Dome Caps Filter Washers Pressure Balance Kit Fitting Instructions Registration Card Concealing Plate Dogleg Thread Adaptor Dome Cap Fitting Instructions IMPORTANT!
Page 4
4. PLEASE READ THIS IMPORTANT SAFETY INFORMATION Products manufactured by the MX Group are safe and without risk provided they are installed, used and maintained in good working order in accordance with our instructions and recommendations. Layout and sizing of pipework MUST be such that when other services are used, pressures at the shower control inlets do not fall below the ...
5. SITE REQUIREMENTS The installation must be in accordance with Water affected by other taps elsewhere in the house. It is Regulations Advisory Service (www.wras.co.uk). very important that for use in any mains pressure systems an expansion tank and a pressure reducing Minimum running water pressure: 0.1 bar, but will valve has been fitted to ensure the pressure does operate better at a minimum of 0.5 bar.
The MX Options range of thermostatic mixer valves is n The mixer valve is suitable for installation on a solid suitable for use with the following systems:...
Page 7
9. FITTING THE MIXER VALVE EXPOSED OPTION IMPORTANT: Ensure that you have read through section 7. IMPORTANT INSTALLATION INFORMATION before starting to fit the mixer valve. 1. Your thermostatic concentric mixer valve is set up in the factory so that a shower hose can be fitted. This means that when the valve is fitted with the hot water coming in from the left hand side, indicated by the red spot, the water outlet is on the bottom of...
Page 8
10. FITTING THE MIXER VALVE CONCEALED OPTION IMPORTANT: Ensure that you have read through section 7. IMPORTANT INSTALLATION INFORMATION before starting to fit the mixer valve. 1. The fitting of the mixer valve is essentially the same 7. The trim plate disc is fitted by pushing it onto the as described for the exposed option, except that the mixer valve until flush with the tiles (Fig 5).
11. OPERATION One control handle controls both flow and temperature. TO CONTROL THE FLOW Pull the control handle outwards, towards you to turn on and increase the flow. Push inwards, away from you to decrease the flow and turn off. TO CONTROL THE TEMPERATURE A numbered dial on the control handle indicates the direction for hot and cold flow.
Page 10
12. COMMISSIONING AND ANNUAL MAINTENANCE TESTING TEMPERATURE SETTING ADJUSTMENT Before commissioning the following checks and tests need to have taken place: NOTE: Adjustment of the temperature settings is only • All the pipe work has been flushed through before to be carried out by a competent TMV engineer as it is fitting the valve and there are no leaks.
13. TROUBLESHOOTING AND FREQUENTLY ASKED QUESTIONS If the performance of your shower deteriorates in service please follow the self help items detailed below before seeking professional advice from the installer. If the actions below fail to restore the shower performance you should initially contact the person or company that installed the shower.
Page 12
7. This guarantee applies only to the product itself and as a result and date of purchase when contacting MX Group. any liability attributed to MX Group is limited to the cost of the The company reserves the right, in the event of a claim not product.
14. SERVICE POLICY 15. SPARE PARTS In the event of you needing to contact the MX Group In the event that parts or maintenance is needed outside the guarantee MX will endeavour to help Customer Service Department, the following with this. Spare parts codes are given in the fitting procedure should be followed: instructions.
Page 16
6754V KL/JULY2016 Marleton Cross Limited Trading as The MX Group Alpha Close, Delta Drive, Tewkesbury Industrial Estate, Tewkesbury, Gloucestershire GL20 8JF Tel: 01684 293311 Fax: 01684 293900 Email: sales @ mx-group.com www.mx-group.com CUSTOMER CARE: 0845 5052211 TRADE DESCRIPTIONS ACT Variations in terms of colour finish, materials and all other aspects of appearance may occur on occasions, either through non-availability of materials or due to our policy of continuing technical improvement.
Need help?
Do you have a question about the Options Sequential and is the answer not in the manual?
Questions and answers