Thermostatic mixer valve for round and square valve options (13 pages)
Summary of Contents for MX Atmos Cool Touch
Page 1
Atmos Cool Touch Thermostatic Bar Mixer Valve with Riser Rail Fitting Instructions IMPORTANT! This Step-by-Step guide should be retained after installation.
Page 2
1. INTRODUCTION This booklet contains all the necessary fitting and pressure. The mixer valve must not be subjected to operating instructions for your MX Thermostatic bar water temperatures above 80˚C. This mixer valve is mixer shower. also suitable for thermal storage, unvented systems and pumped gravity systems.
3. PACK CONTENTS • Riser Rail Bracket Please make sure ALL components are included before starting the installation. • Riser Rail Description Quantity • 6-Mode Handset Bar Mixer Valve 6 Mode Handset Riser Rail • Handset Height Riser Rail Fixing Brackets Adjuster Handset Height Adjuster 1.5m Hose + Washers...
Page 4
4. PLEASE READ THIS IMPORTANT SAFETY INFORMATION Products manufactured by the MX Group are safe and without risk provided they are installed, used and maintained in good working order in accordance with our instructions and recommendations. Layout and sizing of pipework MUST be such that when other services are used, pressures at the shower control inlets do not fall below the ...
5. SITE REQUIREMENTS The installation must be in accordance with Water affected by other taps elsewhere in the house. It is Regulations Advisory Service (www.wras.co.uk). very important that for use in any mains pressure systems an expansion tank and a pressure reducing Minimum running water pressure: 0.1 bar, but will valve has been fitted to ensure the pressure does operate better at a minimum of 0.5 bar.
6. IMPORTANT INSTALLATION INFORMATION Before proceeding with the installation check all the n The mixer valve hot water inlet has a red symbol components in the component list are present. next to the inlet and must be on the left hand side. If the mixer valve you are fitting is with a riser rail the WARNING! outlet should point down, if the mixer valve is for an...
Page 7
8. FITTING THE MIXER VALVE 1. The supply pipework can be plumbed from above or below but must finish at the suitable connections, which should be at 150mm centers. An Easy Fit Kit can be purchased to make installation easier if required.
Page 8
10. FITTING THE RISER RAIL AND HANDSET Establish height of riser rail to suit users requirements (Fig 1). 2. Remove end bracket cover, to explore fitting point from upper of lower brackets (Fig 2). 3. Drill and plug the wall and fix the lower bracket without the rail locator notch.
Page 9
11. COMMISSIONING AND ANNUAL MAINTENANCE TESTING TEMPERATURE SETTING ADJUSTMENT Before commissioning the following checks and tests need to have taken place: NOTE: Adjustment of the temperature settings is only • All the pipe work has been flushed through before to be carried out by a competent TMV engineer as it is fitting the valve and there are no leaks.
12. TROUBLESHOOTING AND FREQUENTLY ASKED QUESTIONS If the performance of your shower deteriorates in service please follow the self help items detailed below before seeking professional advice from the installer. If the actions below fail to restore the shower performance you should initially contact the person or company that installed the shower.
Page 11
7. This guarantee applies only to the component itself and any MX Group at their discretion undertake to repair or replace without liability on behalf of MX Group is limited to the cost of the charge, provided the component has been properly installed, component.
MX. 15. SPARE PARTS In the event that parts or maintenance is needed outside the guarantee MX will endeavour to help with this. Spare parts codes are given in the fitting instructions. By calling the Customer Service Department on 0845 505 2211 with the part number, they will be able to quote you to supply these parts, usually via our spares distributor.
Need help?
Do you have a question about the Atmos Cool Touch and is the answer not in the manual?
Questions and answers