Philips LC9.2A Service Manual page 26

Table of Contents

Advertisement

EN 26
5.
LC9.2A LA
Set is starting up normally but no
display.
Program "Display Option" code via 062598
MENU, followed by 3 digits code (this code
can be found on the side sticker of the set or
service manual).
After entering "Display Option" code, set is
going to Standby (= validation of code).
Restart the set.
Connect PC via ComPair interface to Service
connector at side-AV.
Launch ComPair with correct FF database
Program "Model no.", "Serial no.", "IPB/PSU
12NC" and "Display 12NC".
2010-Jul-01
Service Modes, Error Codes, and Fault Finding
START
Set is still
operating?
Go to SAM mode and save the TV settings
via "NVM Copy to USB".
- Replace SSB board by a Service SSB.
- Make the SSB fit mechanically to the set.
Start-up set.
Set behaviour?
Set is starting up & display is OK.
Saved settings
No
on USB stick?
Yes
Go to SAM mode, and reload settings
via "NVM Copy from USB".
If not already done;
Check latest software on Service website.
Update all relevant software via USB.
Check and perform alignments in SAM
according to the Service Manual.
E.g. option codes, colour temperature...
Final check of all menus in CSM.
Special attention to "Model no. serial no.,
panel code & HDCP keys status".
END
Figure 5-15 SSB replacement flowchart
No
Set is starting up in "Factory" mode.
Top right corner displayed "F" or "cF"
Press 5 s. the "Vol -" & "CH -" button on the local
keyboard until the OSD "F" or "cF" dissappeared.
Unplug the mainscord to verify the correct
disabling of the factory-mode.
- Verify "Option Codes" according to back sticker of set
or service manual.
- Default settings for White drive see Table 6-1
18490_207_090409.eps
090409