Operating Conditions :4 - Panasonic HIT VBHN330SA16 Installation Manual

Hit vbhnxxxsa16 series photovoltaic module
Hide thumbs Also See for HIT VBHN330SA16:
Table of Contents

Advertisement

The clamps should be made of aluminum
alloy
or
other
material
reasonably
protect
against
electrolytic corrosion.
Figure 1-2 shows using a bolt and nut for
mounting.
Recommendation of bolt torque: 10 ft-lbs.
The module was tested using Unirac or
IronRidge clamps with the specifications
see figure 1-1 and below;
1)
Unirac clamps:
Provider: Unirac, Inc.
Product Line: SolarMount
Clamps type: Top Mounting
(Mid clamp and End clamp)
Unirac Part No. 302022C, 302022D,
302027C, 302027D
Width: Mid clamp; 1.5"(38 mm), End
clamp; 1.9"(48 mm)
Thickness:
Mid
clamp;
thickness 0.075"(1.9mm), End clamp;
Nominal thickness 0.125"(3.17mm)
Torque: 13.6 N.m(10 ft-lbs).
Material: Mid clamp; 300 Stainless
steel, End clamp; 6000 Aluminum
alloys
Note: Please refer to Unirac manual,
for installation method.
2)
IronRidge clamps:
Provider: IronRidge Inc.
Product Line: RoofMount
Clamps type: Top Mounting
(Grounding
mid
clamp
clamp)
IronRidge Part No. RS-GD-MCL-225,
RS-GD-MCL-225B,
29-7000-224,
7000-224B
Width:
Grounding
1.16"(29.5 mm), End clamp; 1.5"(38
mm)
Thickness:
Grounding
Nominal
thickness
End
clamp;
Nominal
0.125"(3.17mm)
Torque: 9.5 N.m (85 in-lbs).
Material: Grounding mid clamp; 304
Stainless steel, End clamp; 5000 &
6000 Aluminum alloys
Note:
Please
refer
manual, for installation method.
Panasonic does not provide a warranty
for
clamps.
The
module
Panasonic provides shall be
clamps selected by the customer are of an
improper material or size
Operating Conditions
Panasonic requires that modules are operated
within the following Operating Conditions:
Terrestrial
applications
1)
space or Special Conditions (see below).
2) The
operating
temperature
within –40°C (-40 °F) to 85°C (185 °F).
3) The wind pressure load of the installation
site
should
be
less
(50PSF)
that
will
a
risk
of
Clamps
Nominal
Clamps
and
End
29-
mid
clamp;
mid
clamp;
0.11"(2.85mm),
thickness
to
IronRidge
warranty
voided if
only-no
outer
must
be
2
than
2,400N/m
Installation (reference)
Mid Clamp
(2 places)
End Clamp
(2 places)
Mounting
Structure Rail
End Clamp
Mounting
Rail
<Cross section of clamps>
Overlap range ≧ 0.24" (6mm)
Mid clamp
<Unirac clamps>
Mid clamp
<Ironridge clamps>
Grounding Mid clamp
Figure 1-1. Installation
4
Solar Module
Mid Clamp
Solar Module
Structure
End clamp
End clamp
End clamp

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hit vbhn330sa16bHit vbhn325sa16Hit vbhn325sa16b

Table of Contents