100414 - 2000W PORTABLE INVERTER GENERATOR

TROUBLESHOOTING

Problem
Generator will not start.
Generator will not start;
Generator starts but runs roughly.
Generator shuts down during operation.
Generator cannot supply enough power
or overheating.
No AC output.
Generator gallops.
Repeated circuit breaker tripping.
For further technical support:
Technical Support Team
Toll Free 1-877-338-0999
support@championpowerequipment.com
Cause
No fuel.
Faulty spark plug.
Unit loaded during start up.
Low oil level.
Choke in the wrong position.
Spark plug wire loose.
Out of fuel.
Low oil level.
Overload condition
Overheat condition
Generator is overloaded.
Insufficient ventilation.
Cable not properly connected.
Connected device is defective.
Circuit breaker is open.
Loose wiring.
Other.
Engine governor defective.
Overload.
Faulty cords or device.
26
TROUBLESHOOTING
Solution
Add fuel.
Replace spark plug.
Remove load from unit.
Fill crankcase to the proper level.
Place generator on a flat, level surface.
Adjust choke.
Attach wire to spark plug.
Fill fuel tank.
Fill crankcase to the proper level. Place generator
on a flat, level surface.
Remove load, press reset button
Let generator cool down
Review load and adjust. See "Connecting
Electrical Loads."
Check for air restriction. Move to a well ventilated
area.
Check all connections.
Replace defective device.
Reset circuit breaker
Inspect and tighten wiring connections.
Contact the help line.
Contact the help line.
Review load and adjust. See "Connecting
Electrical Loads."
Check for damaged, bare or frayed wires. Replace
defective device.