Pmfy-P20Vbm-E - Mitsubishi Electric City Multi PMFY Series Technical & Service Manual

Split-type, heat pump air conditioners, ceiling cassettes
Table of Contents

Advertisement

6
WIRING DIAGRAM

PMFY-P20VBM-E

A.B
SW5
220V
240V
(RED)
ADDRESS
SW1
CN43
1 2 3 4 5 6 7 8 9 10
SW12
SW11
SW14
SWC
0
0
10ths
1s
BRANCH
No.
DIGIT
DIGIT
[ LEGEND ]
SYMBOL
NAME
I.B
INDOOR CONTROLLER BOARD
CONNECTOR
HUMIDIFIER
CN25
DAMPER
CN27
REMOTE SWITCH
CN32
HA TERMINAL-A
CN41
CENTRALLY CONTROL
CN51
CN52
REMOTE INDICATION
SWITCH
CAPACITY CODE
SW2
MODE SELECTION
SW3
MODEL SELECTION
SW4
VARISTOR
ZNR
FUSE(6.3A/250V)
FUSE
AUX.RELAY
DRAIN PUMP
X1
T
TRANSFORMER
POWER SUPPLY(I.B)
LED1
POWER SUPPLY(I.B)
LED2
A.B
CIRCUIT BOARD
SWITCH
MODE SELECTION
SW1
VOLTAGE SELECTION
SW5
ADDRESS SETTING 1s DIGIT
SW11
SW12
ADDRESS SETTING 10ths DIGIT
BRANCH NO.
SW14
NOTES:
1. At servicing for outdoor unit, always follow the wiring diagram of outdoor unit.
2. In case of using MA-Remote controller, please connect to TB15. (Remote controller wire is non-polar.)
3. In case of using M-NET, please connect to TB5.(Transmission wire is non-polar.)
4. Symbol [S] of TB5 is the shield wire connection.
5. Symbols used in wiring diagram above are,
6. The setting of the SW2 dip switches differs in the capacity. For the detail, refer to the table above.
7. Please set the switch SW5 according to the power supply voltage. Set SW5 to 240V side when the power supply is 230 and 240 volts.
When the power supply is 220 volts, set SW5 to 220V side.
OC307F
PMFY-P25VBM-E
FUSE
BREAKER
PULL BOX
(15A) (15A)
TO NEXT
INDOOR UNIT
TB2 L
N
PE
I.B
FAN
(WHT)
RED
BLU
CND
(RED)
POWER
BLU
DP
BLU
CNP
(YLW)
D.U.M
*See fig:W1
4
3
2
1
8
7
(RED)
6
ADDRESS
5
CN82
4
0
3
2
1
SYMBOL
NAME
MF
FAN MOTOR
MV
VANE MOTOR
DP
DRAIN PUMP
DS
DRAIN SENSOR
TB2
TERMINAL
POWER SUPPLY
TB5
BLOCK
TRANSMISSION
TB15
MA-REMOTE CONTROLLER
TH21
THERMISTOR
ROOM TEMPERATURE DETECTION
(0:/15k", 25:/5.4k")
TH22
PIPE TEMPERATURE DETECTION/LIQUID
(0:/15k", 25:/5.4k")
TH23
PIPE TEMPERATURE DETECTION/GAS
(0:/15k", 25:/5.4k")
LEV
LINEAR EXPANSION VALVE
LED on indoor board for service
Mark
Meaning
LED1
Main power supply
Power supply for
LED2
MA-Remote controller
: terminal block,
PMFY-P32VBM-E
POWER SUPPLY
TO OUTDOOR UNIT
~/N 220-230-240V 50Hz
BC CONTROLLER
220V 60Hz
REMOTE CONTROLLER
DC24-30V
TB5
M1 M2
MF
5
CN2M
1
2
(BLU)
M-NET
LED1
1
2
3
4
5
6
FUSE
3
1
ZNR
CN41
(WHT)
CN51
T
(WHT)
CENTRALLY
1
CONTROL
3
X1
X1
CN52
(GRN)
REMOTE
INDICATION
SW2
SW3
0N
0FF
1
2
3
4
5
6
1
2
3
4
5
6
7
8
9
10
1
(WHT)
(RED)
(RED)
REMOTE
ADDRESS
ADDRESS
SWITCH
CN32
CN42
CN81
1 2
3
4
1
2
3 4 5 6 7 8
3
1
4
8
MODELS
P20VBM
P25VBM
P32VBM
P40VBM
The black square (
Function
Main power supply(Indoor unit:220-240V)
power on
Lamp is lit.
Power supply for MA-Remote controller
on
Lamp is lit.
: connector.
17
PMFY-P40VBM-E
(SHIELD)
TO MA-REMOTE CONTROLLER
DC8.7-13V
1 2
TB15
CN3A
1
2
(BLU)
3
REMOCON
CN31
(WHT)
2
DRAIN
1
LED2
CN29
2
(BLK)
1
GAS
CN21
2
(WHT)
1
LIQUID
CN20
2
(RED)
1
INTAKE
BLU
6
BRN
4
5
ORN
CN60
4
YLW
(WHT)
3
HA
LEV
RED
2
1
WHT
1
5
1
6
BRN
5
5
RED
CN6V
4
ORN
(GRN)
3
VANE
YLW
1
2
GRN
1
SW4
0N
2
0FF
1
2 3 4 5
CN25
2
1
CN27
<W1>
SW2
SW3
0N
0N
0FF
0FF
1
2
3
4
5
6
123456
7
8
9
10
0N
0N
0FF
0FF
1
2
3
4
5
6
123456
7
8
9
10
0N
0N
0FF
0FF
1
2
3
4
5
6
123456
7
8
9
10
0N
0N
0FF
0FF
123456
1
2
3
4
5
6
7
8
9
10
) indicates a switch position.
DS
TH23
TH22
TH21
6
LEV
1
2
3
MV
4
5

Advertisement

Table of Contents
loading

Table of Contents