Toro ProLine 30441 Operator's Manual page 37

Mid–size mower proline hydro 17 hp with 52in side discharge mower
Hide thumbs Also See for ProLine 30441:
Table of Contents

Advertisement

3. Using the bolt and nut, connect the positive (red cover)
cable to the positive (+) battery post (Fig. 39). Slide
the rubber cover over the battery post.
4. Using the bolt and nut, connect the negative (black)
cable to the negative (–) battery post (Fig. 39). Slide
the rubber cover over the battery post.
5
2
3
9
7
10
Figure 39
1. Negative cable
2. Nut (1/4 in.)
3. Nut (5/16 in.)
4. Bolt
5. Rubber cover (red)
6. Rubber cover (black)
Checking Electrolyte Level
1. With the engine off, locate the battery.
2. Look at the side of the battery. The electrolyte must be
up to the upper line (Fig. 40). Do not allow the
electrolyte to get below the Lower line (Fig. 40).
1
2
3
Figure 40
1. Filler caps
2. UPPER line
6
8
1
4
11
m–7583
7. Positive cable
8. Battery hold down plate
9. Washer
10. Battery hold down
11. Battery
3. LOWER line
37
3. If the electrolyte is low, add the required amount of
distilled water; refer to Adding Water to the Battery,
page 37.
Danger
Battery electrolyte contains sulfuric acid which is
a deadly poison and causes severe burns.
Do not drink electrolyte and avoid contact with
skin, eyes or clothing. Wear safety glasses to
shield your eyes and robber gloves to protect
your hands.
Fill the battery where clean water is always
available for flushing the skin.
Follow all instructions and comply with all
safety messages on the electrolyte container.
Adding Water to the Battery
The best time to add distilled water to the battery is just
before you operate the machine. This lets the water mix
thoroughly with the electrolyte solution.
1. Remove the battery from the machine.
2. Clean the top of the battery with a paper towel.
Note: Never fill the battery with distilled water while the
battery installed in the machine. Electrolyte could be
spilled on other parts and cause corrosion.
3. Remove the vent caps from the battery (Fig. 40).
4. Slowly pour distilled water into each battery cell until
the level is up to the Upper line (Fig. 40) on the
battery case.
Important
Do not overfill the battery because
electrolyte (sulfuric acid) can cause severe corrosion and
damage to the chassis.
5. Wait five to ten minutes after filling the battery cells.
Add distilled water, if necessary, until the electrolyte
level is up to the "UPPER" line (Fig. 40) on the
battery case.
6. Reinstall battery vent caps.
Charging the Battery
Warning
Charging the battery produces gasses that can
explode.
Never smoke near the battery and keep sparks
and flames away from battery.

Advertisement

Table of Contents
loading