Fixing The Installation Plate - Samsung AJ040 Series Manual

Table of Contents

Advertisement

Fixing the installation plate

You can select the direction of the drain hose depending on where you want to install the indoor unit. Therefore before fixing
the installation plate to a wall or a window frame, you must determine the position of the 65mm hole through which the cable,
pipe and hose pass to connect the indoor unit to the outdoor unit.
When facing the wall, the pipe and cable can be connected from the:
• Right (A)
• Left (B)
• Underside_right (C)
• Rear_right or left (D)
1. Determine the position of the pipe and drain hose hole as seen in the picture and drill the hole with an inner diameter
of 65mm so that it slants slightly downwards.
Pipe hole
(Ø65mm)
B
2. Fix the indoor unit.
If you fix the indoor unit on a wall
(1) Fix the installation plate to the wall giving attention to the weight of the indoor unit.
• I f you mount the plate to a concrete wall using plastic anchors, make sure that gaps
between the wall and the plate, created by projected anchor, is less than 20mm.
If you fix the indoor unit on a window frame
(1) Determine the positions of the wooden uprights to be
attached to the window frame.
(2) Attach the wooden uprights to the window frame giving
attention to the weight of the indoor unit.
(3) Attach the installation plate to the wooden upright using
tapping screws.
• S earch for other spots if there are less than two studs, or the distance between the studs are different from the
plate hanger.
• Fix the installation plate without inclining to one side.
• M ake sure that a wall can withstand the weight of the product. If you install the product in a place where it is
not strong enough to withstand the product weight, the unit could fall and cause injury.
 Direction of pipe
A
D
C
Model
020/025/035
050/068
C
English-31
B
D
(Unit : mm)
A
B
C
D
30
96
38
30
38 126 70
38
If you fix the indoor unit on a gypsum board
(1) Use stud finder to find out locations of the studs.
(2) Fix the plate hanger on two studs.
• M ake sure to drill only one
hole after choosing the
direction of the pipe.
Plastic
Anchor
Wall
<20mm

Advertisement

Table of Contents
loading

Table of Contents