Sanyo SAP–KR184GJ Technical & Service Manual page 35

Split system air conditioner
Table of Contents

Advertisement

C. Check remote control unit.
• Try to run with another remote
control unit.
First remote control unit is defective.
• Check for residue buildup on
transmitter of remote control unit.
• Check for residue buildup on remote
control receiver on front of indoor
unit.
D. Check fuse on the indoor PCB Ass'y.
• Check fuse on indoor PCB Ass'y
for continuity.
• Check operation lamp to see
if light is ON.
• Indoor PCB Ass'y is defective.
E. Check TIMER on the remote control unit.
• Timer is turned ON. Check to see
if
is displayed on remote
ON
control.
OK
If fuse has been blown,
OK
Light is OFF
YES
• Replace the fuse.
• Measure resistance of indoor and
outdoor fan motor winding.
• Measure resistance of compressor
motor winding.
Cancel the timer mode.
35
Clean transmitter.
Clean receiver.
(FM)
(CM)

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sap–cr184gSap–kr224gjSap–cr224g

Table of Contents