7. INSTALLATION INSTRUCTIONS

7-1. Installation Site Selection

Indoor Unit
WARNING
AVOID:
direct sunlight.
nearby heat sources that may affect performance of
the unit.
areas where leakage of flammable gas may be
expected.
places where large amounts of oil mist exist.
DO:
select an appropriate position from which every
corner of the room can be uniformly air-conditioned.
(High on a wall is best)
select a location that will hold the weight of the unit.
select a location where tubing and drain hose have
the shortest run to the outside.
allow room for operation and maintenance as well as
unrestricted air flow around the unit. (Fig. 1)
install the unit within the maximum elevation
difference (H) above or below the outdoor unit and
within a total tubing length (L) from the outdoor unit
as detailed in Table 1 and Fig. 2a.
Table 1
Model
KR184
KR224
∗ If total tubing length becomes 7.5 to 30m (max.) or 10 to 30m (max.), charge additional refrigerant (R410A) by 25 g / m.
No additional charge of compressor oil is necessary.
         
To prevent abnormal heat
generation and the possibility
of fire, don't place obstacles,
enclosures and grilles in front
of or surrounding the air
conditioner in a way that may
block air flow.
Max. Allowable Tubing
Length at Shipment
(m)
7.5
10
Wall-mounted Type
5 cm
min.
INDOOR
UNIT
Elevation
difference (H)
For stable operation of
the air conditioner, do not
install wall-mounted type
indoor units less than
1.5m from floor level.
Limit of Tubing
Limit of Elevation
Length (L)
(m)
30
30
23
15 cm min.
INDOOR UNIT
Front View
Fig.1
Tubing length (L)
OUTDOOR
UNIT
Fig. 2a
Fig. 2
CAUTION
Indoor Unit
Minimum height
from floor level
1.5m
Floor level
Fig. 2b
Required Amount of
Difference (H)
Additional Refrigerant
(m)
7
7
5 cm
min.
Wall
(g / m) ∗
25

Hide quick links: