Advertisement

Quick Links

USER MANUAL
B series
File: R-B-044-01-08 B-41_3 GB v.1

Advertisement

Table of Contents
loading

Summary of Contents for Axis B0.6D

  • Page 1 USER MANUAL B series File: R-B-044-01-08 B-41_3 GB v.1...
  • Page 2: Table Of Contents

    USER MANUAL _____________________________________________________________________________________________________________________ Contents: 1. General description....................... 3 2. Completeness ....................... 3 3. Technical data....................... 4 4. Keys and indicators....................... 5 5. Security rules ........................ 6 6. Environment protection ....................6 7. Preparation ........................7 8. Start-up ......................... 7 9. General rules ........................ 8 10.
  • Page 3: General Description

    USER MANUAL _____________________________________________________________________________________________________________________ 1. General description B series technical scales are destined for general use. All scales are metrologically tested - calibration or legal verification on demand. Standard B/E scales are equipped with the display mounted on the post for easy readout of weighing result.
  • Page 4: Technical Data

    USER MANUAL _____________________________________________________________________________________________________________________ 3. Technical data Scale type B0.6D B1.5D B15D B0.6* B1.5* B10* B15* Capacity 0,6kg 1.5kg 10kg 15kg 100g Minimum load *20g *20g Readability(d) 0,2g 0,5g *0,1g *0,1g *0,1g *0,1g *0,2g Verification unit (e) 0,2g 0,5g Accuracy class Working temperature -10÷40°C...
  • Page 5: Keys And Indicators

    USER MANUAL _____________________________________________________________________________________________________________________ 4. Keys and indicators MODE - switch-on / switch-off (standby), - tare (subtract package weight from weighed mass) → ← - gross weigh indication switch, - zero, → ← MENU - special functions menu, - print-out, - increased indication resolution, indicator - zero indicator →...
  • Page 6: Security Rules

    USER MANUAL _____________________________________________________________________________________________________________________ 5. Security rules To avoid electrical shock or damage of the scale or connected peripheral devices, it is necessary to follow the security rules below. All repairs and necessary regulations can be made by authorised personnel • only.
  • Page 7: Preparation

    USER MANUAL _____________________________________________________________________________________________________________________ 7. Preparation 1. Take the scale out of the package removing protective foils. 2. Take a pan off and remove protective elements from below the pan. 3. Place the scale on a stable ground not affected by mechanical vibrations and airflows.
  • Page 8: General Rules

    USER MANUAL _____________________________________________________________________________________________________________________ 9. General rules 1. Before each measurement make sure that zero indicator is displayed. If zero indicator does not displayed or “----“ communicate appears, press →0← key and wait until zero indication and zero indicator appears. 2. The scale is equipped with a tare equal to its range. To tare the scale press →T←...
  • Page 9: Scale Adjustment

    (optional) used for example for continuous weighing result transmission to an additional, external display. When cooperating with the scale, a computer should be equipped with a program which enables processing data from the scale – available in AXIS with extra charge.
  • Page 10 USER MANUAL _____________________________________________________________________________________________________________________ Computer cooperation protocol: Transmission parameters: 8bits, 1stop, parity ODD, 4800bps. Signal description: Computer→Scale: initialising signal S I CR LF (53h 49h 0Dh 0Ah), Scale→Computer: weighing result according to the diagram below (16 Bytes): Note: Network number different than zero (F..-rS / nr function) changes scale working mode: communication with a computer is possible after logging the scale in with 02h scale_number command.
  • Page 11: Special Functions Description

    USER MANUAL _____________________________________________________________________________________________________________________ 13. Special functions description All scales, beside basic functions like weighing and tare, are equipped with the set of additional functions. Basic set of user special functions consists of: - autozero (AUt), - pieces counting (PCS), - constant tare (tAr), - serial port working mode setting (LPt), - serial port parameters setting (rS), - menu customisation (ACt).
  • Page 12: Normal Weighing

    USER MANUAL _____________________________________________________________________________________________________________________ 14. Normal weighing →0← key, which zeros the scale, operates only when the pan is empty. Weighing result should be read when the indicator " " lights. 15. Weighing with tare The scale is equipped with tare equal to its range.
  • Page 13: Increased Readability

    USER MANUAL _____________________________________________________________________________________________________________________ 16. Increased readability Press HR key to display the weighing result (for 5s.) with the highest readability possible. This function is especially helpful in scales with legal verification with d=e. 23.4g The weighing result with increased readability used informational purposes only and cannot be printed or sent to a...
  • Page 14: Autozero (F

    USER MANUAL _____________________________________________________________________________________________________________________ 17. Autozeroing (F..-AUt) When F..-Aut function is activated, the scale automatically ensures stable zero indication if the pan is empty or if zero indication was acquired by F.. -AUT → ← pressing key. To leave the function press MENU →...
  • Page 15: Pieces Counting (F

    USER MANUAL _____________________________________________________________________________________________________________________ 18. Pieces counting (F..-PCS) This function enables to count identical pieces, e.g. turnbuckles or buttons. A measurement is performed in two phases: - first phase - single piece weight calculation on the basis of defined pieces amount (5, 10, 20, 50, 100, 200 or 500 pieces), - second phase –...
  • Page 16: Printer Cooperation Settings (F

    USER MANUAL _____________________________________________________________________________________________________________________ 19. Printer cooperation settings (F..-LPt) Activate the function for automatic serial port working mode (cooperation with a printer). After activation the scale prints a header. Weighing result with F.. -LPt a successive measurement number is printed automatically after result stabilisation (without using key).
  • Page 17: Serial Port Parameters Setting (F

    USER MANUAL _____________________________________________________________________________________________________________________ 20. Serial port parameters setting (F..-rS) The function enables to set the following transmission parameters (standard parameters underlined): F.. -rS - transmission speed (bAud: 1200, 4800, 9600), - the number of bits in a byte (bIt: 7, F..
  • Page 18: Constant Tare (F

    USER MANUAL _____________________________________________________________________________________________________________________ 21. Constant tare (F..-tAr) This function enables to measure gross weight of a sample placed in a container of a known weigh value (stored in the memory) and to display calculated net weight → ← of the sample. Tare value is recalled from the memory with key when the pan is empty.
  • Page 19 USER MANUAL _____________________________________________________________________________________________________________________ Weighing with constant tare: When tAr function is activated, press → ← key to zero the indication and -3.7g to recall tare value from the memory. Tare value is displayed with ”-” sign. enables instant switching between net and gross weight.
  • Page 20: Function Menu Customisation (F

    USER MANUAL _____________________________________________________________________________________________________________________ 22. Function Menu customisation (F..-ACt) This function enables to select special functions that will be displayed after pressing MENU key. Easy access to the most useful functions will shorten F..-ACt operation time and make work more comfortable. Operation sequence shown on the F..-AUt picture, presents how to add RS232C...
  • Page 21: Maintenance And Repairs Of Small Defects

    USER MANUAL _____________________________________________________________________________________________________________________ 23. Maintenance and repairs of small defects 1. The scale should be kept clean. 2. Take care that no dirt gets between the platform and the scale base. If found any, remove the pan (lift it up), remove dirt and then replace the pan. 3.
  • Page 22: Declaration Of Conformity

    USER MANUAL _____________________________________________________________________________________________________________________ Declaration of Conformity AXIS Spółka z o.o. 80-125 Gdańsk, ul. Kartuska 375B confirm with all responsibility that scales: B0.6, B1.5, B2, B3, B6, B10 i B15 B0.6D, B1.5D, B2D, B3D, B6D i B15D marked with CE mark comply with the following: 1.
  • Page 23 USER MANUAL _____________________________________________________________________________________________________________________ Notes...
  • Page 24 USER MANUAL _____________________________________________________________________________________________________________________...

Table of Contents