Yaesu FT-857 Technical Supplement page 15

Hf/vhf/uhf ultra-compact transceiver
Hide thumbs Also See for FT-857:
Table of Contents

Advertisement

FM TX IF Adjustment
1. Tune the frequency to the 28 MHz band. Connect the
RF millivoltmeter to TP1033 on the MAIN Unit.
2. Disconnect the Coaxial Cable from J1002 and termi-
nate J1002 into a 50-Ohm dummy load.
3. Key the transmitter in the FM mode, and adjust T1014
for maximum indication on the RF millivoltmeter.
4. Connect the frequency counter to TP1033.
5. Key the transmitter in the FM mode without micro-
phone input. Adjust L1049 for a reading of 68.3300
MHz (±100 Hz).
6. Disconnect the 50-Ohm dummy load and re-connect
the Coaxial Cable to J1002.
Carrier Balance Adjustment
1. Tune the frequency to the 14 MHz band. Disconnect
the Coaxial Cable from J1002 on the MAIN Unit.
2. Terminate J1002 into a 50-Ohm dummy load and con-
nect a spectrum analyzer or a RF millivoltmeter at this
point.
3. Key the transmitter in the USB mode without micro-
phone input. Adjust VR1005 for maximum carrier sup-
pression on the spectrum analyzer or for minimum in-
dication on the RF millivoltmeter.
4. Disconnect the 50-Ohm dummy load and the spectrum
analyzer or the RF millivoltmeter, and re-connect the
Coaxial Cable to J1002.
T1024
T1019
T1018
T1026
T1028
TP1044
T1029
T1030
T1034
T1035
T1027
T1036
T1037
TX BPF Adjustment
VHF TX BPF Adjustment
1. Set the frequency to 145.995 MHz. Disconnect the
Coaxial Cable from J1002 on the MAIN Unit.
2. Connect the spectrum analyzer to J1002, which should
be terminated into a 50-Ohm dummy load.
3. Inject a 1 kHz tone at 1 mV level to the MIC jack.
4. Key the transceiver in the USB mode, and adjust
T1013, T1012, and T1011 alternately for maximum
indication on the spectrum analyzer.
5. Disconnect the 50-Ohm dummy load and the spectrum
analyzer, and re-connect the Coaxial Cable to J1002.
UHF TX BPF Adjustment
1. Set the frequency to 430.000 MHz. Disconnect the
Coaxial Cable from J1002 on the MAIN Unit.
2. Connect the spectrum analyzer to J1002, which should
be terminated into a 50-Ohm dummy load.
3. Inject a 1 kHz tone at 1 mV level to the MIC jack.
4. Key the transceiver in the USB mode, and adjust
TC1004, TC1003 and TC1002 alternately for maxi-
mum indication on the spectrum analyzer.
5. Disconnect the 50-Ohm dummy load and the spectrum
analyzer, and re-connect the Coaxial Cable to J1002.
TC1004
MAIN Unit Alignment Points III
TC1003
TC1002
Alignment
TC1005
T1008
T1010
T1005
T1009
T1006
T1004
TC1001
T1031
TP1043
15

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ft-857d