46
en | Recovering the unit
7.2.3

Foreign configuration disk appears in the Windows GUI after booting

The RAID is degraded. Topology error is shown. Right-click Megaraid Controller in the MSM
GUI. Click "scan foreign configuration". In the next window, click "clear foreign configuration".
An unconfigured good drive is displayed. Right-click this drive and choose a hotspare type.
You see the rebuild is starting at once.
2014.12 | V4 | DOC