Onboard Control Menus; Single Head Module Operation - Martin MAC 401 Dual User Manual

Hide thumbs Also See for MAC 401 Dual:
Table of Contents

Advertisement

Onboard control menus

Single head module operation

When only one module is installed on the head, the HEAD menu is automatically set to SNGL. The MAC
401 automatically detects whether an RGB Zoom or CT Zoom module is installed and adjusts the control
menu accordingly. The following control menus are available:
Menu
ADDR
DMX
PERS
36
Item
Options
1
– XXX
RAWX
PSET
RGBX
(fixture auto-
HSX
detects which
RAW
module is
installed and
RGB
displays either
1
HS
RGB/HS
or
2
CT
menu
CTX
items)
CT
1
2H
PGRP
2V
All
OFF
PINV
ON
PTSP
SWAP
PTST
PINV
TINV
REG
FULL
FANS
SLNT
LIN
SQR
DIM
ISQR
SCUR
OFF
DRES
ON
ON
2MN
DISP
5MN
10MN
DINT
0-100
NORM
ERRM
SLNT
WITH
CTC
(RGB Zoom
INDP
module only)
Table 6: Control menu: single head module operation
MAC 401™ user manual
Notes (Default settings in bold print)
DMX address (default address = 1). The DMX address range is limited
so that the fixture will always have enough DMX channels in the 512
available.
Non-calibrated RGB mode with dynamic effects
Calibrated RGB mode with dynamic effects
HSV mode with dynamic effects
Non-calibrated RGB mode without dynamic effects
Calibrated RGB mode without dynamic effects
HSV mode without dynamic effects
CT mode with dynamic effects
CT mode without dynamic effects
Individual control of 4 pixels (segments)
Control of pixels in 2 groups of 2 pixels, horizontal split
Control of pixels in 2 groups of 2 pixels, vertical split
All pixels controlled as one group
Disable pixel inversion
Pixel inversion: pixels swapped left to right and top to bottom
Pan and tilt speed normal / fast
Swap pan and tilt (pan commands move tilt and vice versa) - off / on
Pan inversion (reverse direction pan control) - off / on
Tilt inversion (reverse direction tilt control) - off / on
Cooling fan speed thermostatically regulated
Max. cooling fan speed
Silent mode. When Silent mode is selected the head fan will turn off.
The base fan will still run. Values allowed for RGB or HSV (no matter
what operating mode) will be limited to prevent the fixture from
producing too much heat. If the LEDs get too hot the fans will revert to
Regulated mode. When the LEDs are cool enough the fans shift back to
Silent mode. The color wheel channel will have lower intensity in Silent
mode.
Linear dimming curve
Square law dimming curve
Inverse square law dimming curve
S-curve dimming curve
Disable reset via DMX
Enable reset via DMX
Display is permanently on
Display switches off and goes into Sleep mode if controls have not
been pressed for 2 minutes.
Display switches off and goes into Sleep mode if controls have not been
pressed for 5 minutes
Display switches off and goes into Sleep mode if controls have not been
pressed for 10 minutes
Display intensity. Default = 100%
Display errors at 100% intensity (regardless of
illuminate the service light.
Silent error mode. The error message does not appear in the display,
but the service lamp is illuminated
Sending a value on a CTC channel adjusts the temperature of
whatever color is currently being displayed on segment or fixture
Sending a value on a CTC channel overrides any color being displayed.
Fixture or segment switches to white with variable color temperature
1
1
1
1
1
1
2
2
DINT
setting) and

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mac 401 ct zoom

Table of Contents