VIII. REMOVAL AND REPLACEMENT OF COMPONENTS
1. REFRIGERATION CIRCUIT
This machine contains flammable refrigerant. Do not attempt to break into the
refrigerant circuit unless qualified, competent and authorised to do so.
If any component of the refrigeration circuit requires removal or replacement, please
contact the manufacturer:
HOSHIZAKI EUROPE LIMITED
Telford 70 Stafford Park 7, Telford, Shropshire TF3 3BQ UK
Tel: +44 (0)1952-291777
Fax: +44 (0)1952-292777
[a] APPLICABLE PARTS
Refrigerant (R290)
Compressor
Evaporator Casing
Air-cooled Condenser
Air-cooled Condenser Fan Motor
Drier
Thermal Expansion Valve (with MOP)
[b] SERVICE INSTRUCTIONS
Always restore the original bindings after servicing the refrigeration circuit. Otherwise,
vibration may cause overstress and damage to the circuit, resulting in refrigerant leak.
After replacing the Evaporator or Auger, run the icemaker for 30 minutes to produce ice,
check for impurities, and discard.
[c] REFRIGERANT
The HFC-free refrigerant is flammable and sealed in the refrigeration system. Although
the refrigerant does not leak out under normal usage, take utmost care when handling
this icemaker so as not to cause any damages to the system. In the case of accidental
damage to the refrigeration system causing refrigerant leak, do not create a source of
ignition in the area. Do not operate electrical switches or plugs in the area, do not use
naked flame. Immediately ventilate the area by opening doors and/or windows.
WARNING