Disconnecting All Connections ([D]Disconnect All); Entering Advanced Setup Menu ([A]Advanced Setup); Setting Auto Logout Time (Advanced[1]Auto Logout Time); Data Port Setting (Advanced[2]Data Port) - Sharp XG-C465X-L Setup Manual

Hide thumbs Also See for XG-C465X-L:
Table of Contents

Advertisement

Setting up the Projector Using RS-232C or Telnet
Disconnecting All Connec-
tions
([D]Disconnect All)
It is possible to disconnect all the TCP/IP connec-
tions currently recognized by the projector. Even if
the COM Redirect port is fixed in the Busy status
due to a problem, it is possible to force the Ready
status back by carrying out this disconnection.
setup>d
Disconnect All Connections(y/n)?y
Now Disconnecting...
1 1 1 1 1 Enter "d" and press the "Enter" key.
2 2 2 2 2 Enter "y" and press the "Enter" key.
Note
• If Disconnect All is performed, the connection to
the projector via network will be forcibly discon-
nected.
Entering ADVANCED
SETUP MENU
([A]Advanced Setup)
Enters ADVANCED SETUP MENU.
setup>a
******************** ADVANCED SETUP MENU ***********************
[1]Auto Logout Time
[2]Data Port
[5]Network Ping Test
[6]Accept IP Addr(1)
[7]Accept IP Addr(2) [8]Accept IP Addr(3)
[9]Accept All IP Addr
[0]Search Port
[!]Restore Default Setting
[Q]Return to Main Menu
advanced>
1 1 1 1 1 Enter "a" and press the "Enter" key.
-36
Setting Auto Logout Time
(ADVANCED[1]Auto Logout Time)
If there is no input after a fixed time, the projector
automatically disconnects network connection using
the Auto Logout function. It is possible to set the time
until the projector is automatically disconnected in
units of a minute (from 1 to 65535 minutes).
advanced>1
1
Valid range
2
note: if you enter "0", auto logout function will be disable.
Auto Logout Time : 5
Please Enter
(change)
—> 15
1 1 1 1 1 Enter "1" and press the "Enter" key.
2 2 2 2 2 Enter numerical value and press the "Enter" key.
Display set numerical value (*).
Note
• If the set value is made 0, the Auto Logout func-
tion is disabled.
• If an invalid number is entered, an error message
("Parameter Error!") will be displayed and the
screen returns to the ADVANCED SETUP MENU.
Data Port Setting
(ADVANCED[2]Data Port)
1
Setting of TCP port number. It is possible to set in
the range of 1025 to 65535.
advanced>2
Valid range
Data Port
Please Enter
(change)
—> 10005
1 1 1 1 1 Enter "2" and press the "Enter" key.
2 2 2 2 2 Enter numerical value and press the "Enter" key.
Display set numerical value (*).
Note
• Set according to need. Normally, use with the fac-
tory default setting.
: 0 to 65535 (minute)
:15
:1025 to 65535
:10002
:10005
1
2
*
1
2
*

Advertisement

Table of Contents
loading

This manual is also suitable for:

Xg-c435x-l

Table of Contents