C. C. C. C. C. REMOVING BLOWER MOTOR
REMOVING BLOWER MOTOR
REMOVING BLOWER MOTOR
REMOVING BLOWER MOTOR
REMOVING BLOWER MOTOR
(Figure 11 (Front View)
(1) Disconnect wires from Blower Motor.
(2) Unhook Control Frame after removing the screw.
(3) Remove 3 front screws securing the Blower Base.
D. D. D. D. D. REMOVING MAGNETRON
REMOVING MAGNETRON
REMOVING MAGNETRON
REMOVING MAGNETRON
REMOVING MAGNETRON
(Figure 12)
After removing the Blower Motor :
(1) Remove 4 screws and disengage Space Partition.
(2) Disconnect lead wire from the Magnetron.
(3) Remove 4 screws securing the Magnetron to the
Waveguide.
(4) Take out Magnetron VERY CAREFULLY.
1.
When removing the magnetron from the cavity or
wave guide, use a proper care so that the dome of
the magnetron does not hit any adjacent parts of
microwave oven.
2.
Make sure that the contact face of the magnetron
gasket is free from any damage or deformation.
3.
Adjust the position of the magnetron properly, so
that it correctly sits in place and the magnetron
gasket is in contact with the mounting rim evenly.
4.
While holding the magnetron under this condition,
tighten mounting screws or nuts with your fingers
temporarily.
5.
Further tighten the screws or nuts with a box
wrench, giving one or two turns to each of the
screws (or nuts) alternatively so that the
magnetron is mounted on to the bracket uniformly.
6.
After replacing the magnetron, be sure to check the
microwave energy leakage with a leakage detector
and confirm the leakage is below 4mW/cm
NOTE
NOTE
NOTE
NOTE
NOTE
H.V. Transformer
.
2
Magnetron
- 12 -