High-Voltage Capacitor; High-Voltage Diode - Sanyo EM-S9000S Supplement Of Service Manual

Table of Contents

Advertisement

COMPONENT
COMPONENT
COMPONENT
COMPONENT
COMPONENT
Measure the resistance : Across two terminals
with an ohm-meter on highest scale.
HIGH-VOLTAGE
CAPACITOR
including
BLEEDER
RESISTOR
Measure the resistance : Across two terminals
with an ohm-meter on R x 10,000 scale.
HIGH-VOLTAGE
DIODE
Measure the voltage : Between test point TP-1,
TP-2, TP-3, TP-4 or TP-5 and Ground between
TP-6 and TP-7 (See Control Circuit Board on
page 19).
CONTROL
CIRCUIT
BOARD
- Proceed with the check of the Step-Down
Transformer, to see if any one of the measured
values is different from the specified values.
CHECKOUT PROCEDURE
CHECKOUT PROCEDURE
CHECKOUT PROCEDURE
CHECKOUT PROCEDURE
CHECKOUT PROCEDURE
Ohm-meter
Ohm-meter
Ohm-meter
Ohm-meter
Ohm-meter
Ohm-meter
Ohm-meter
Ohm-meter
Ohm-meter
Ohm-meter
NOTE
NOTE
NOTE
NOTE
NOTE
Normal reading :
Momentarily indicates several ohms,
and gradually returns to 10 meg-ohms.
Abnormal reading :
Indicates continuity or 10 meg-ohms
from the beginning.
Figure 7
Figure 7
Figure 7
Figure 7
Figure 7
Normal reading :
Indicates about the middle position in
one direction (forward direction) and
infinite ohms in the reverse direction,
using meter which is provided with a
9 volt battery.
- Some digital meter may show over
even in a forward direction because
low measuring voltage of meter does
not allow the meter current to pass
through the high voltage diode.
Abnormal reading :
Indicates continuity or infinite ohms
in both directions.
Figure 8
Figure 8
Figure 8
Figure 8
Figure 8
Test
Point
Voltage
Test
Point
Voltage
- 5 -
RESUL
RESUL
RESUL
RESULT T T T T
RESUL
NOTE
NOTE
NOTE
NOTE
NOTE
TP-1
TP-2
TP-3
-5V
-15V
-25V
DC
DC
DC
TP-6/
TP-4
TP-5
TP-7
-27V
-31V
2.0V
DC
DC
AC

Advertisement