Machine Operation - KleenRite MegaXL 36306 Operator And Parts Manual

Water extractor and pump, 15 gal extractor
Table of Contents

Advertisement

OPERATION
Fig. 3
4. Place recovery tank lid in operating position
(Figure 5).

MACHINE OPERATION

PRE-OPERATION
1. Inspect power cord for damage.
2. Turn on empty-out pump (Figure 6). The
discharge pump will not come on when the "Auto
Discharge" switch is turned "ON". Note: the "Auto
Discharge" switch must be turned on in order for
the discharge pump to evacuate the recovered
water. Turn this pump "OFF" when done with job.
Fig. 6
3. Securely fasten dump hose and drain to an
appropriate area designated approved by local
code.
EXTRACTING WATER
1. Activate both vacuums (Figure 7).
2. Take extraction wand in hand and move the tool
in short forward and backward strokes.
WHILE OPERATING
1. Overlap each path by 50 mm (2 in).
2. Periodically check for excessive foam buildup in
recovery tank. Use a recommended foam control
solution to prevent vacuum motor damage.
8
Fig. 4
Fig. 5
Fig. 7
ATTENTION: Excessive foam buildup will not
activate the float shut-off screen.
ATTENTION: Discharge pump will not pump foam.
Use a defoamer.
USING THE MEGAXL WITH WEIGHTED
EXTRACTION TOOL
1. If using a weighted extraction tool with the
MEGAXL in a full lockdown condition, periodically
remove the vacuum release plug from the
vacuum lid (Figure 8). After a few minutes it can
be returned to its normal operating position to
achieve maximum vacuum. This action on the
part of the operator is necessary to prevent
overheating of the vacuum.
DRAINING RECOVERY TANK
1. Turn off machine after majority of water has been
pumped out by discharge pump.
2. Insert supplied 45º elbow in drain valve. Place a
bucket below it and slowly pull up on handle
(Figure 9).
Fig. 8
Fig. 9
36306 & 36306CETL(8-16)

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Megaxl 36306cetl

Table of Contents