TROUBLESHOOTING GUIDE
Problem
Possible Causes
Espresso:
1a. No water in water
tank.
1. Coffee does
not come out
when brewing
espresso.
1b. Espresso grind is too
fine.
1c. Espresso grinds were
tamped with too much
pressure.
1d. Too much espresso in
the filter.
1e. Filter is clogged and
needs to be cleaned.
1f. Appliance is not
turned ON.
2a. Ground coffee is too
2. Coffee comes
coarse.
out too quickly.
2b. Not enough coffee in
and/or is too
filter.
weak.
"0" on the display.
No water is in water tank.
The display is
The knob was turned
blank when trying
directly from the "steam"
to brew coffee and
position to the "brew"
the ready indicator
position without being
light is flashing.
in the "standby" position
for approximately 35
seconds.
Steam is emitted
The Coffee House has
from the drip
overheated and entered
tray and the
the automatic cool-down
pump operates
cycle where it will purge
intermittently.
excess water and steam
from inside the unit into
the drip tray.
The drip tray fills
The Coffee House has
with water on its
gone through a few
own.
automatic cool-down
cycles, where it will purge
excess water and steam
from inside the unit into
the drip tray.
The unit has
There is a 5 minute
automatically
Auto off function on the
switched off.
machine.
12
VCF117_19EM1 (UK).indd 12-13
Solutions
1a. Add water to water tank and turn
the knob to the "standby" position
for approximately 35 seconds.
Then, turn the knob back to the
"brew" position.
1b. Grind coffee to espresso ground
level of fineness.
1c. Tamp (press) the espresso grinds
with less pressure.
1d. Fill the filter with less coffee.
1e. Clean the filter.
1f. Plug the Coffee House into
electrical outlet.
2a. Use a finer ground coffee.
2b. Use more coffee.
Add water to water tank and turn the
knob to the "standby" position for
approximately 35 seconds.
Turn the knob to the "standby"
position for approximately 35
seconds. When the ready indicator
light turns solid, turn the knob to the
"brew" position to continue.
The Coffee House will complete
the automatic cool-down cycle. The
ready indicator light will pulse during
the cool- down cycle and will turn
solid when the cycle is complete.
When the water level indicator rises,
pull out the drip tray and discard the
water.
Press any button to reactivate the
unit.

REPLACEMENT PARTS

For additional or replacement parts, please
visit www.breville.co.uk or call us on
0161 621 6900.
TROUBLESHOOTING
For troubleshooting and FAQs visit:
www.breville.co.uk/faqs

ELECTRICAL SAFETY

This appliance must be earthed.
If the plug is not suitable for the socket
outlets in your home, it can be removed
and replaced by a plug of the correct type.
If the fuse in a moulded plug needs to be
changed, the fuse cover must be refitted.
The appliance must not be used without
the fuse cover fitted.
If the plug is unsuitable, it should be
dismantled and removed from the supply
cord and an appropriate plug fitted as
detailed. If you remove the plug it must not
be connected to a 13 amp socket and the
plug must be disposed of immediately.
If the terminals in the plug are not marked
or if you are unsure about the installation
of the plug please contact a qualified
electrician.
Plug should be ASTA approved to BS1363
Fuse should be ASTA approved to BS1362
Green/Yellow
(Earth)
13A Fuse
Blue
(Neutral)
Brown
(Live)
Ensure that the outer sheath of