Eagle Signal B506 Technical Manual

Eagle Signal B506 Technical Manual

High performance led timer
Hide thumbs Also See for B506:

Advertisement

Introduction
Your Eagle-Signal brand B506 1/16 DIN timer is a powerful instrument which can be
field configured to fit a wide variety of applications. The secondary setpoint can be
used for a second time output, combining the function of two timers in a single
package, or as a batch counter to track the amount of completed cycles. 1 ms
resolution with transistor outputs make this unit well suited for high speed
processes.
Inside this manual you will find complete information on the Control mode, which
deals with viewing and changing the available setpoints, and Program Mode which is
used to configure the basic operation of the timer, as well as set a variety of other
useful features.
Also found in this manual are detailed timing diagrams and descriptions of the
available operating functions to aid you in determining how to properly configure the
unit to solve your application. Additionally included are key product specifications,
warranty procedures and ordering
information should you require additional
units or accessories.
Should you require any additional
assistance with the installation and
operation of this product, please call our
toll free application support line at 1-800-
234-8731.
Features
• 17 Different, field programmable, modes of
operation
• Batch Count function with timed or
latched output
• Dual setpoints in many modes
• Simple button per digit interface
• Timing resolution down to 1 ms
• Programmable security levels prevent
unauthorized setpoint or program changes
• High Visibility LED display of both time
value and setpoint
• Available with relay or solid state outputs
• IEC IP65 rated front panel
• Repeatability of 0.01%
• Inhibit input halts timing without
resetting the cycle
Index
Overview
Panel Mounting
page 2
Wiring Connections
page 2
Operation
Front Panel
page 3
Control Mode
page 4
Configuration
Program Mode
page 5 - 7
Timing Diagrams
page 8- 12
Program Flow Chart
page 13
General
Specifications
page 14
Ordering Information
page 14
Notes Sheet
page 15
Warranty
page 16
Technical Manual
702118-0001
Eagle Signal
brand
B506
High
Performance
LED Timer
1

Advertisement

Table of Contents
loading

Summary of Contents for Eagle Signal B506

  • Page 1 Introduction Your Eagle-Signal brand B506 1/16 DIN timer is a powerful instrument which can be field configured to fit a wide variety of applications. The secondary setpoint can be used for a second time output, combining the function of two timers in a single package, or as a batch counter to track the amount of completed cycles.
  • Page 2: Installation

    (–) AC Power Warning: Do Not connect a coil in parallel with the start signal for the B506, as pictured at left. Such a connection will cause the start signal to be continuously active. This situation also applies to the Reset and Inhibit inputs.
  • Page 3: Front Panel Operation

    Illuminates to display when an input or output is operation the illuminated LED will flash. active: "IN' for the start input, "O1" and "O2" for the timed outputs. EAGLE SIGNAL Batch Indicator 1234 Illuminates to indicate that the Batch Count Preset 2 Indicator Value and Batch Preset are being displayed.
  • Page 4: Control Mode

    O P E R A T I O N CONTROL MODE Preset 1 Display EAGLE SIGNAL EAGLE SIGNAL EAGLE SIGNAL 0000 0000 0000 25:00 25:01 25:11 Top display: Time Value for P1 Operation Pressing the numeric keys will cause the corresponding digit to increment by a value of one (i.e.
  • Page 5: Program Mode

    C O N F I G U R A T I O N PROGRAM MODE • Enter the Program Mode by holding down the "P" key for 3 seconds • Press the "P" key to move the top display from one parameter to the next •...
  • Page 6 C O N F I G U R A T I O N For Interval 1 and Interval 2: Begin Together (bt): Preset 2 is set as an independent time interval which will begin timing and activate Output 2 upon initiation of the start signal . End Together (Et): Preset 2 is set as a value relative to Preset 1.
  • Page 7 C O N F I G U R A T I O N Timing Direction: Determines whether the time values for Preset 1 and 2 will increment from t d i r zero and change the state of the output at the set value (uP) or decrement from the set value and change the state of the output at zero (dn).
  • Page 8: Timing Diagrams

    C O N F I G U R A T I O N TIMING DIAGRAMS On Delay - Absolute On Delay - Prewarn Start Start Out 1 Out 1 Out 2 Out 2 Reset Reset Activates Deactivates Activates Deactivates On leading edge of start Preset 1 On completion of P1 or Preset 1...
  • Page 9 C O N F I G U R A T I O N On Delay w/Batch On Delay/Interval w/Batch Start Start Out 1 Out 1 Out 2/ Out 2/ Batch Batch Reset Reset Activates Deactivates Activates Deactivates On leading edge of start On leading edge of start Preset 1 On completion of P1 or...
  • Page 10 C O N F I G U R A T I O N Interval 1 - End Together Interval 2 - End Together Start Start Out 1 Out 1 Out 2 Out 2 Reset Reset Activates Deactivates Activates Deactivates On completion of P1, deasser- On completion of P1, deasser- Preset 1 On leading edge of start...
  • Page 11 C O N F I G U R A T I O N Interval 1 - Batch Interval 2 - Batch Start Start Out 1 Out 1 Out 2/ Out 2/ Batch Batch Reset Reset Activates Deactivates Activates Deactivates On completion of P1, deasser- On completion of P1 or Reset Preset 1 On leading edge of start...
  • Page 12 C O N F I G U R A T I O N On/Off Delay - Batch Count Accumulative - Absolute P1-T Start Start t1 + t2 + t3 = P1 Out 1 Out 1 Out 2/ t1 + t2 + t3 + t4 = P2 Batch Out 2 Reset...
  • Page 13: Programming Overview

    C O N F I G U R A T I O N PROGRAMMING OVERVIEW OFdL, OnOF, dint Func out2 H:M or M:S trn1 dEc1 out2 * If Delay/Interval or On/Off are selected as the Operating Function, Out2 is automatically set to Batch. However, the P2 setting is still available, and the second time range is available.
  • Page 14: Ordering Information

    ORDERING INFORMATION Description Model # Description Model # High Performance Timer, Relay Out, 90-240 VAC B506-2001 11 Pin Socket - DIN Rail Mount 60SR2P06 High Performance Timer, Relay Out, 24 VDC/AC B506-2002 11 Pin Socket - Outward facing terminals PBT-03172...
  • Page 15 G E N E R A L NOTES...
  • Page 16: Warranty

    G E N E R A L WARRANTY Standard B506 products manufactured by the Company are Products which the Company consents to have returned shall be warranted to be free from defects in workmanship and material for shipped F.O.B. the Company's factory. The Company cannot assume...
  • Page 17 X-ON Electronics Largest Supplier of Electrical and Electronic Components Click to view similar products for manufacturer: Veeder Root Other Similar products are found below : 0166726-006 0195316-051 0116425-007 RFMT00R RFMV00 RFXDC10 RFXP10 RFXS00 RFXT00 C342-0462 C346-0422 C628-20052 C628-20300 C628-40050 C628-41002 C628-41300 C628-70002 C628-81002 C628-90000 C628-91002 S628-20300 A103-A14 RFMSK00 RFMT00 RFMV00R RFXD00 RFXD10 RFXS10 C342-1562 C342-3462 C346-0513 C628-20000 C628-20002 C628-21350 C628-40000 C628-40052 C628-41302 C628-51002 C628-60002 VC773-342 0317680-001 0703006-003 0726845-001 0727245-001 0743425-003 0743425-005 0743797-001 0744386-211 0745815-001 0779526-201...

Table of Contents