On/off controller with user adjustable analog input three/five independent discrete outputs and an analog transmitter output

Advertisement

Quick Links

COMPETENCE IN
MEASUREMENT
ON/OFF controller
with user adjustable analog input
three/five independent discrete outputs
and an analog transmitter output
MS8104k5 & MS8104k3
v2.01
USER MANUAL
PLOVDIV 2015
Document revision 2015-03-16

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MS8104k5 and is the answer not in the manual?

Questions and answers

Summary of Contents for microSYST MS8104k5

  • Page 1 COMPETENCE IN MEASUREMENT ON/OFF controller with user adjustable analog input three/five independent discrete outputs and an analog transmitter output MS8104k5 & MS8104k3 v2.01 USER MANUAL PLOVDIV 2015 Document revision 2015-03-16...
  • Page 2: Table Of Contents

    DESIGNATION MS8104k5 and MS8104k3 are designed for process control in ON / OFF control mode. The difference between the two controllers is only in the number of discrete outputs - 5 for MS8104k5 and 3 MS8104k3. One of discrete outputs is alarm with switch-on delay and the rest are ON / OFF controlled with programmable hysteresis All outputs have independent set points, and user selectable positive or negative logic of control / type "heating"...
  • Page 3: Order Code

    The difference between two models are the number and type of the digital outputs only Digital outputs К1.К2.K3 0 - No MS8104k3 - x.x. .x.х.x. 1 - Relay 5A/250VAC SPDT 2 - Triac 2A / 250VAC MS8104k5 - x.x. .x.х.x. xxxxх nsulated 3 - NPN OC =65V, I =100mA...
  • Page 4: Technical Data

    TECHNICAL DATA Inputs Linear current or voltage current - 0 (4) ÷ 20 mA DC, voltage - 0 ÷ 1 (10) V DC Pt 100, P1000 EN 60751 Thermocouple J, K, S, B, R, E EN 60584 Other by order Measurement accuracy ±...
  • Page 5: Front And Back Panel. Display And Keyboard

    4. FRONT AND BACK PANEL. DISPLAY AND KAYBOARD MS8104-k3 Power Supply 26 25 23 22 20 19 www.microsyst.net 12 13 GND IN +Vexc MS8104-k5 Power Supply 26 25 23 22 20 19 www.microsyst.net 12 13 GND IN +Vexc Document revision 2015-03-16...
  • Page 6: Connections

    5. CONNECTIONS Connection of an analog input  RTD Sensors - Pt100, Pt1000 and others Thermocouple 1 2 3 Shorted on the sensor 1 2 3 1 2 3 three wire two wire Compensating cable connection connection Transmitters 1 2 3 1 2 3 1 2 3 U power...
  • Page 7: Operation

    K1 LED is illuminated when the output K1 is turn on, K2 LED is illuminated when the output K2 is turn on. AL LED is illuminated when the alarm output is turn on. Outputs K3 and K4 is indicated on the front panel only for MS8104k5 with 20mm digits. In this mode, the action of the buttons is as follows:...
  • Page 8: Lock / Unlock The Keyboard

    The single entering of this combination (pressing of the button UP, holding and pressing of the button AUTO) when the input variable is on the display will realize locking of the keyboard. By the second entering of this combination will unlock the keyboard.
  • Page 9: System Parameters Setting

    7.3. System parameter setting Parameters accessible at pressed button at switch on of the power supply.  The System Parameters apear after basic parameters.  Access is possible by holding the button up to power supply turn off  Change with extreme caution, because their change can result in incorrect operation of the appliance! Changing the P1 and P0 required standard device connected to the output.
  • Page 10: Analog Output

    7.4. Analog output The analog output is with digital range Aout = 0 ÷1023. ● The analog output is calculated with: ● Aout = ( P1 . (PV – dSPL low limit ) + P0) / 1024 (dSPH high limit – dSPL low limit ) Offet seting of the analog output Press and hold the button before turn on the power supply if the keyboard ...
  • Page 11: Service Functions- Available Only In Service Description

    SERVICE FUNCTIONS OF THE CONTROLLER ( only in SERVICE DESCRIPTION ) THEY CAN BE USED FROM SERVICE SPECIALIST ONLY! INCORRECT USAGE OF THIS FUNCTIONS CAUSE DISABILITY OF THE DEVICE! Document revision 2015-03-16...
  • Page 12 Service Type of the repair of the entry number delivery repair Seller: ....Buyer: ....България, 4000 гр. Пловдив, ул. Мургаш 4 Тел.: (+359 32) 642 519, 640 446 факс: (+359 32) 640 446 www.microsyst.net e-mail: info@microsyst.net Document revision 2015-03-16...

This manual is also suitable for:

Ms8104k3

Table of Contents