UNPACKING
The Air Cleaner is shipped complete in one carton. Carefully unpack the Air
Cleaner and all loose items from the carton. WARNING: DO NOT LIFT THE
AIR CLEANER BY ITS POWER CORD.
WARNING: STYROFOAM BLOCKS PLACED AROUND THE MOTOR AND
IMPELLOR MUST BE REMOVED BEFORE OPERATING AIR CLEANER.
1) Pivot the upper and lower filter retaining clips (A) Fig.4 and pull out the outer
and inner filters (B).
2) Remove the steel meshing (C) inside the air cleaner and remove the
styrofoam blocks (D).
3) Reinstall the steel meshing, inner and outer filters and secure the filters with
the retaining clips.

SETTING UP THE AIR CLEANER

Operational tips:
• This Air Cleaner will work best if it is located away from corners and heating/
cooling vents.
• This air cleaner is specifically designed to circulate and filter non-metallic
dust, which is generated throughout the work area.
Hanging air cleaner from ceiling
1) This Air Cleaner can be hung from the ceiling. Remove the four large pan
head screws (A) Fig.5 from the top of the air cleaner housing using a Philips
screwdriver.
2) Install the four air cleaner eye bolts (B) Fig.5 to the top of the air cleaner
housing.
3) Mount ceiling hooks and chains (not included) properly rated for hanging
this unit (minimum 60 lbs capacity) in the ceiling to mount the air cleaner.
Mounting air cleaner to ceiling or wall
1) Four brackets (A) Fig.6 can also be used for mounting to a ceiling or wall.
2) Place one end of bracket underneath the lip of the air cleaner cabinet (B).
3) Secure the bracket (A) to the cabinet with two hex. bolts, spring washers
and washers (C) as shown in Fig.6. Repeat steps for the remaining three
brackets.
4) Secure air cleaner to ceiling or wall with appropriate hardware (not
included).
WARNING! Ceiling hooks or mounting brackets must be anchored to the
building structure, which will support a minimum of at least 100 pounds. Never
mount to drywall or false ceiling grids. Hang/mount unit with a 7ft. clearance
from the floor.