Wireless detector

Advertisement

7 Configuration
The device's loop address is configured within the menu structure
of the Radio Hub.
Refer to the programming manual (Doc Ref: MK98) for full
programming information.
Specification
Operating
Temperature
-10°C to 55°C
Storage
Temperature
5°C to 30°C
Humidity
Up to 95% non-condensing
Supply
6x AA Alkaline (Panasonic LR6AD Powerline /
Varta 4006 Industrial)
CAUTION!
Fitting of an incorrect battery type invalidates the product certification and
may result in poor performance.
IP Rating
IP23
Operating
Frequency
868MHz
Output
Transmitter
Power
Auto adjusting 0 - 14 dBm (0 - 25 mW)
Dimensions
113mm (Ø) 40mm (D) (without detector)
113mm (Ø) 76mm (D) (with smoke detector)
113mm (Ø) 81mm (D) (with heat detector)
113mm (Ø) 87mm (D) (with multisensor detector)
Weight
0.40kg (with detector)
Location
Type A: For indoor use
©2020 EMS Ltd. All rights reserved
Free to download from
www.emsgroup.co.uk
Page 2 of 2
IMPORTANT
!
Remove dust cover before use.
The device should be tested upon installation and in accordance
with local requirements.
Testing should only be carried out by a fully trained competent
person.
The Manufacturer recommends regular functional testing of at
least once per annum or in accordance with local codes of
practice.
Cleaning and repairs must be undertaken by the Manufacturers
authorised representative.
Do not open the case to clean inside the detector.
Regulatory Information
Manufacturer
EMS Ltd. Technology House, Herne Bay, Kent,
CT6 8JZ, United Kingdom
Year of
manufacture
See devices serial number label
10
Certification
0905
Certification body
CPR Certificate
See part listing for associated products:
DOP
[1]0359-CPR-0015, [2]0359-CPR-0017,
[3]0359-CPR-0041 & [4]0905-CPR-202126
Approved to
See part listing for associated products:
EN54-5:2001. Incorporating Amendment No. 1.
Fire detection and fire alarm systems.
Part 5: Heat detectors - Point Detectors.
EN54-7:2001. Incorporating Amendment No. 1. Fire
detection and fire alarm systems.
Part 7: Smoke detectors - Point detectors using
scattered light, transmitted light or ionization.
EN54-25:2008.Incorporating corrigenda September
2010 and March 2012. Fire detection and fire alarm
systems.
Part 25: Components using radio links.
European Union
EMS declares that the radio equipment type FireCell
directives
Detector
2014/53/EU. The full text of the EU declaration of
conformity is available at the following internet
address: www.emsgroup.co.uk
2012/19/EU (WEEE directive):
Products marked with this symbol cannot be
disposed of as unsorted municipal waste in the
European Union. For proper recycling, return this
product to your local supplier upon purchase of
equivalent new equipment, or dispose of it at
designated collection points. For more information
see www.recyclethis.info
Dispose of your batteries in an environmentally
friendly
regulations.