Suunto D9 Instruction Manual page 97

Hide thumbs Also See for D9:
Table of Contents

Advertisement

5. Carefully remove the battery. Do not touch the electrical contacts or the circuit
board
Check for any traces of fl ooding, or for any other damage. In case of a leak or any ot-
her damage, bring the transmitter to an authorized SUUNTO dealer or distributor for
check and repair.
6. Check the condition of the O-ring; a defective O-ring may indicate sealing or
other problems. Dispose the old O-ring, even if it seems to be in good conditi-
on.
7. Check that the o-ring groove and the sealing surface of the cover the are
clean. Clean with soft cloth if necessary.
8. Gently insert the new battery in the battery compartment. Check the polarity of
the battery: the "+" mark should point toward the top of the compartment and
the "-" mark towards the bottom.
NOTE! It is imperative to wait at least 30 seconds before re-installing the transmitter
battery.
When the battery is re-installed the transmitter sends an overpressure ("---") signal on
code 12 for 10 seconds, after which it goes to normal operation, and shuts down af-
ter 5min.
9. Check that the new lubricated O-ring is in good condition. Put it in the right po-
sition in the o-ring groove. Be very careful not to get any dirt on the o-ring or
its sealing surfaces.
95