Requirement: The drain pump is
empty. → Page 35
Because water may remain in the
1.
drain pump, remove the pump cap
carefully.
Clean the inside and the thread on
2.
the pump cap and pump housing.
Make sure that the impeller in the
3.
drain pump can be turned.
Insert the pump cap and screw it
4.
on.
90°
Cleaning and servicing en
The handle on the pump cap must
be in a vertical position.
Insert the maintenance flap and
5.
lock it into place.
1
Close the maintenance flap.
6.

Before the next wash

To prevent unused detergent from
flowing straight into the outlet in the
next wash, run the Drain ‫ تفريغ‬pro-
gramme after you have emptied the
drain pump.
Turn on the tap.
1.
Insert the mains plug.
2.
Switch on the appliance.
3.
Pour 1 litre of water into compart-
4.
ment II.
Start the Drain ‫ تفريغ‬programme.
5.
Cleaning the water outlet
hose at the siphon
If the water outlet hose at the siphon
is dirty or the detergent solution is
not being pumped out, you must
clean these.
Switch off the appliance.
1.
Disconnect the appliance's mains
2.
plug from the power supply.
Loosen the hose clamp and care-
3.
fully remove the water outlet hose.