ACCESSORIES
Connection
Description
Cables
BA300
CAB-AUX03 M12 3P TO DB9
Service
SERIAL CABLE 3M
BA400
CAB-PW-EXT M12 POWER
Ext. Power
EXTENSION CABLE
CBL-1480-01 M12/5P
MALE/FEMALE 1M IDNET
BA600 / BA700
ID-NET Out / In
CBL-1480-02 M12/5P
MALE/FEMALE 2M IDNET
Connectors
BA300
FMC300 M12 3P M. CONN.
SERVICE
BA400
FMC400 M12 3P F. CONN.
POWER
The FMC accessory connectors can be used to make custom External
Power and Service cables in case the standard cables don't satisfy the
application requirements.
GROUNDING
There are two general rules to follow regarding network grounding:
1) The network Shield must only be connected to Earth ground at
one point (the Master).
When using isolated power supplies, Earth grounding can be
accomplished through the CAB-PW-EXT accessory cable and the
BA400 connector.
CAB-PW-EXT
Power Supply
Earth ground connection
2) All reader Chassis must be connected to Earth ground.
All the readers in the network must have their Chassis connected to
Earth ground either by: mounting to conductive metal brackets or
frames; or through the CBX or SC4000; or through the QL bushing.
In the case of grounding through the CBX or SC4000, connect the
Earth signal to a good earth ground and set the internal Chassis
jumper to Earth.
In the case of grounding through the QL bushing, connect a flying
lead from the mounting bushing to an Earth ground. The mounting
bushing is internally connected to the reader Chassis.
TYPICAL LAYOUTS
Part
Number
93A051385
93A051381
93A050049
93A050050
93ACC1883
BA600 ID-NET™ Out
93ACC1884
BA700 ID-NET™ In
BA400 Ext. Power
BA500 Trigger
BA300 Service
BA400 on
Master
Power
CAB-PW-EXT
CBX500 w BM200
ID-NET™ Synchronized Network - Scanner Master with CBX500 / BM2x0 + Scanner Slaves with QL100
ID-NET™ Slave Nodes
CBL-1480-xx
2
CBX100
4
PS
Power
SC4000 Master
The ID-NET network must be terminated
through the internal switch of the SC4000
and the last CBX in the network.
ID-NET™ Multidata Network - SC4000 Master + Scanner Slaves with CBX100
CBL-1480-xx
DS2100N
Master
PS
3
1
4
5
Ethernet
CAB-AUX03
CBL-1480-xx
1
2
4
PS
3
1
5
CAB-AUX03
ID-NET™ Slave Nodes
QL100
CBL-1480-xx
The ID-NET network must be terminated through the
internal switch of the CBX500 and inserting an ID-NET
terminator into the last QL in the network.
Host
BA600 ID-NET™ Out
BA400 Ext. Power
BA500 Trigger
BA300 Service
1
2
4
PS
Host
QL100
CBL-1490
ID-NET
Terminator