BA300 - BA700
M12 PANEL CONNECTORS
INSTALLATION MANUAL
DESCRIPTION
The BAxxx M12 Panel Connectors are accessories for the CBX series
connection boxes and SC4000 Controllers. They provide direct
connection between the box and the network using standard cables.
All the connectors come with IP65 protection caps so that in case of
temporary use, (i.e. Service connector for reader configuration), this
cap can be replaced to maintain IP65 protection when not connected.
IP65 protection is provided when the BAxxx is
correctly mounted to the box and either the IP65
protection cap is in place or the cables are properly
mated.
NOTE
Connector
Description
BA300
Connects to the Aux Port inside the CBX or
Service
SC4000 to allow for software configuration through
an external PC without opening the box therefore
reducing maintenance time.
BA400
Connects to the Vdc and GND terminals as Power
Ext. Power
Input to the box.
BA500
Connects to the Input 1 signals to allow connection
Trigger
to the trigger (presence sensor).
BA600
Provides ID-NET and power signals towards the
ID-NET Out
next device in the network (power Out).
BA700
Provides ID-NET and power signals from the
ID-NET In
previous device in the network (power In).
821001631 (Rev. A)
INSTALLATION
Power must be off during this operation.
CAUTION
The BAxxx Panel Connectors can easily be installed into the CBX series
or SC4000 by substituting any one of the compression connectors and
mounting the M12 Connector in its place.
1. Remove the compression
connector with its retaining
nut.
2. Insert the retaining nut of
the M12 connector.
Retaining Nut
3. Install the M12 connector
passing its wires through
the retaining nut. Tighten
the connector to between 2
and 2.5 Nm so that the
o-ring seals against the
CBX or SC4000 body.
4. Insert the wires into the
relative spring clamp
connectors according to the
pinout tables.
 Using a device such as a
screwdriver, push down
on the lever directly
above the clamp.
 Insert the wire into the
clamp and release the
lever.
BA300 (Service)
M12 3P Female (B-coded)
Pin
Color
Function
1
Brown
RXA
2
White
GND
3
Blue
TXA
BA400 (Ext. Power)
M12 3P Male (B-coded)
Pin
Color
Function
1
Brown
Earth
2
White
Vdc
3
Blue
GND
BA500 (Trigger)
M12 4P Female (A-coded)
Pin
Color
Function
1
Brown
+V
2
White
I1A/B
3
Blue
-V
4
Black
I1A/B
BA600 (ID-NET Out)
M12 5P Female (A-coded)
Pin
Color
Function
1
Brown
Shield
2
White
Vdc
3
Blue
GND
4
Black
ID+
5
Grey
ID-
BA700 (ID-NET In)
M12 5P Male (A-coded)
Pin
Color
Function
1
Brown
Shield
2
White
Vdc
3
Blue
GND
4
Black
ID+
5
Grey
ID-