ELECTRICAL CONNECTION L< 50m (only on special requests)
MAINS
DMX Cable
M20
MAINS Cable
M25
Connection Box
M25
1.6
20
DMX (2 entries)
Cable from Driver box
to Connection Box
MAINS
Ø 13-18mm
DMX
1) Remove plugs only when needed
2) Slip the DMX cable without RJ45
plug through the cable gland
3) Crimp the RJ45 modular plug on
the DMX cable inside the driver
Ø min
Ø max
TORQUE MAX VOLTAGE
(mm)
(mm)
2 x Ø6mm
NA
4.5 Nm
+/-1mm
Ø 13
Ø 18
5 Nm
Ø 13
Ø 18
4.5 Nm
PIN #
1
2
3
6
4
5
7
8
9
Pin numbering and color in accordance with ANSI/TIA/EIA-568
scheme T568B
TERMINATOR RJ45 (not supplied by Philips)
For safety reasons the terminator must have
isolated housing
CONNECTION BOX
STRIPPING LENGTH:
8-9 mm
RECOMMENDED CABLE TYPE
SUPPORTED
1000 V
2x ETHERNET shielded cable CAT5
1000 V
H07RN-F 450V/750V
1000 V
H07RN-F 450V/750 or A11VV U-600/1000V
10/24
L
COLOR
FUNCTION
WHITE/ORANGE
DATA 1+
ORANGE
DATA 1-
WHITE/GREEN
DATA 2+ (Optional)
GREEN
DATA 2- (Optional)
BLUE
Not assigned
WHITE/BLUE
Not assigned
WHITE/BROWN
Signal Common for data 1 (0 V)
BROWN
Signal Common for Data 2 (0 V)
DRAIN
8-9 mm
C O N N E C T O R
SECTION MAX
4 mm2
2.5 mm2