Download Print this page

Instant Upright Ridgeway Step-Up100 Instruction Manual

Podium

Advertisement

Quick Links

Step-Up100 and Step-Up150 Podium
Instruction Manual
DESIGNATION
Step-Up100
(1m Podium)
PAS250-2-1/1-XXCX PS1500
CEN designation of this instruction manual
Step-Up 150 (1.5m Podium)
EN 1298 — IM — en
PAS250-2-1.5/1.5- XXCX
Rev-00

Advertisement

loading

Summary of Contents for Instant Upright Ridgeway Step-Up100

  • Page 1 Step-Up100 and Step-Up150 Podium Instruction Manual DESIGNATION Step-Up100 (1m Podium) PAS250-2-1/1-XXCX PS1500 CEN designation of this instruction manual Step-Up 150 (1.5m Podium) EN 1298 — IM — en PAS250-2-1.5/1.5- XXCX Rev-00...
  • Page 2: Assembly Process

    WARNING NEVER STAND ON AN UNGUARDED PLATFORM SAFE WORKING LOADS AND WORKING HEIGHTS The total loading on the podium structure should not exceed 150kg. Do not extend the build height above that shown in this guide. ASSEMBLY PROCESS 1. Preparation •...
  • Page 3: Care And Maintenance

    • Lightly oil spring mechanisms of the hooks. • For transport and storage, components are best stored vertically. • Damaged parts must be repaired or replaced; refer to the Instant Upright website for further advice or contact your equipment supplier for advice.
  • Page 4 MOVING PODIUM TOWERS To move the podium to a new position, first prepare the podium. • Check that the wind speed does not • Carefully move the podium by manually applying exceed 29km/h (8.1m/s). force at the base. Do not use mechanical means to move the podium.
  • Page 6 Ensure castors are locked Do not use the podium if before use damaged working height platform 2m above platform load 150kg Only access the Single person use only Ensure all hooks Podium using the latches are closed steps provided Never stand on the side Never lift the podium to Do not over-reach protection or use boxes,...
  • Page 7 Never use on Never move whilst a Maximum horizontal person is standing on the load = 10kg sloping or uneven platform surfaces Never work near power lines Never use as a means Ensure all latches of access to another are closed before or other electrical equipment place working from the...