9. TECHNICAL DATA
9.1 Hob dimensions
Width
Depth
9.2 Bypass diameters
BURNER
Triple Crown
Semi-rapid
Auxiliary
9.3 Other technical data
TOTAL POWER:
Electric supply:
Appliance category:
min 6 mm
a
min 30 mm
min 5 mm
(max 150 mm)
60 mm
Gas original:
Gas replacement:
220-240 V ~ 50/60 Hz
3 core flexible cable with non rewireable plug fitted with a 3 amp
cartridge fuse
II2H3+
A. Removable panel
B. Space for connections
Kitchen unit with oven
The electrical connection of the hob and
the oven must be installed separately for
safety reasons and to let easy remove
oven from the unit.
740 mm
510 mm
Ø BYPASS 1/100 mm
57
35
28
G20 (2H) 20 mbar = 10,5 kW
G30 (3+) 28-30 mbar = 763 g/h
G31 (3+) 37 mbar = 750 g/h
ENGLISH