  • Page 1 OPERATING INSTRUCTIONS BAL.NR.00 05 41 39 HM 6 FU 230V HYMIX WE KEEP THINGS MOVING...
  • Page 2: General

    When operated correctly and with careful treatment, the PFT HM 6 will be a true assistant.
  • Page 3 Status 11.2004 ____________________________________________________________________________________________________________ Initial inspection after delivery An indispensable task of all fitters who deliver the PFT HM 6 is to check the machine settings after the initial starting up. The plant settings can change during the initial starting. If these are not corrected in good time, immediately after the warming up, there is a risk of breakdowns.
  • Page 4: Table Of Contents

    ____________________________________________________________________________________________________________ PFT HM 6 FU 230V HYMIX Contents Stand 11.2004 ____________________________________________________________________________________________________________ General ................................1 List of contents..............................3 Overview................................4 Operating and display elements .........................5 Basic safety notices ............................6 Setting values ..............................8 Check list ................................10 Cleaning & measures upon completion of work....................12 Measures in the event of a power failure and danger of frost ................13 Transportation..............................13...
  • Page 5: Overview

    ____________________________________________________________________________________________________________ PFT HM 6 FU 230V HYMIX Overview Status 11.2004 ____________________________________________________________________________________________________________ Tilting motor flange Rubber mixing tube Gear motor 4 KW Mixing shaft Mixing tube HM 6 Mortar outlet flange Metering shafts segment Rubber external bearing Water in-feed 10. Controlling unit _______________________________________________________________________________________ Knauf PFT GmbH &...
  • Page 6: Operating And Display Elements

    ____________________________________________________________________________________________________________ PFT HM 6 FU 230V HYMIX Overview – switch cabinet Status 11.2004 ____________________________________________________________________________________________________________ Motor protection – control transformer 11. Connection – motor cable Vibrator water pump 12. Connection – level indicator probe Pressure reducer 13. Vibrator connection Solenoid valve 14.
  • Page 7: Basic Safety Notices

    _______________________________________________________________________________________________________________ PFT HM 6 FU 230V HYMIX Basic safety notices Status 11.2004 _______________________________________________________________________________________________________________ HM 6 The PFT is a horizontal continuous mixer for factory-style pre-mixed mortar. It has been designed solely for silo operation. Please observe the material manufacturer’s processing guidelines.
  • Page 8 ____________________________________________________________________________________________________________ PFT HM 6 FU 230V HYMIX Basic safety notices Status 11.2004 ____________________________________________________________________________________________________________ All safety and danger information on the machine must be observed and kept in a read- able state! The machine must be checked for any external damage and faults at least once per shift!
  • Page 9: Setting Values

    In accordance with VDE conditions, connect the machine only to an assembly for con- struction site (with stipulated FI safety switch). Use power cable 5x2.5mm² with CEE coupling 400 V, 3x16A PFT article number 20 42 33 50. Connect a mixer motor.
  • Page 10 Setting values and starting up Status 11.2004 ____________________________________________________________________________________________________________ After the horizontal mixer PFT HM 6 has been completely fitted and connected, the following procedure must take place: Open the silo flap. Switch on the PFT HM 6 using the green ON switch.
  • Page 11: Checklist

    _______________________________________________________________________________________________________________ PFT HM 6 FU 230V HYMIX Checklist Status 11.2004 _______________________________________________________________________________________________________________ How can problems with the PFT HM 6 be avoided or quickly remedied? Problem Possible cause Remedy Machine won’t start up! Power - Is the power supply in order? Inspect the fault and remedy.
  • Page 12 _______________________________________________________________________________________________________________ PFT HM 6 FU 230V HYMIX Checklist Status 11.2004 _______________________________________________________________________________________________________________ - Metering and / or mixing shaft is / are blocked. - Too long or too weak power cable. - Too little material in the material con- tainer. _______________________________________________________________________________________ Knauf PFT GmbH &...
  • Page 13: Cleaning & Measures Upon Completion Of Work

    Maintenance and assembly work may only be carried out when the machine is without power (interrupt the power supply). Cleaning With a consistent daily operation, the PFT HM 6 needs only to be cleaned at the end of work. The cleaning is carried out in 5 stages 1.
  • Page 14: Measures In The Event Of A Power Failure And Danger Of Frost

    PFT HM 6 shall again mix normally. Measures in the event of a danger of frost In the event of a danger of frost, the water fitting of the PFT HM 6 must be emptied. To do this:...
  • Page 15: Wiring Diagrams

    ____________________________________________________________________________________________________________ PFT HM 6 FU 230V HYMIX Wiring diagrams Status 11.2004 ____________________________________________________________________________________________________________ _______________________________________________________________________________________ Knauf PFT GmbH & Co. KG Telephone 09323 / 31-760 PO Box 60 09323 / 31-770 D-97343 Iphofen Internet www.pft.de _______________________________________________________________________________________...
  • Page 16 ____________________________________________________________________________________________________________ PFT HM 6 FU 230V HYMIX Wiring diagrams Status 11.2004 ____________________________________________________________________________________________________________ _______________________________________________________________________________________ Knauf PFT GmbH & Co. KG Telephone 09323 / 31-760 PO Box 60 09323 / 31-770 D-97343 Iphofen Internet www.pft.de _______________________________________________________________________________________...
  • Page 17: Spare Parts Lists

    ____________________________________________________________________________________________________________ PFT HM 6 FU 230V HYMIX Spare parts lists Status 11.2004 ____________________________________________________________________________________________________________ Spare parts list – drive motor assembly ......................17 Spare parts list – mixing tube assembly......................19 Spare parts list – water fitting assembly......................21 Spare parts list – switch cabinet assembly.......................23 _______________________________________________________________________________________ Knauf PFT GmbH &...
  • Page 18 ____________________________________________________________________________________________________________ PFT HM 6 FU 230V HYMIX Spare parts list – drive motor assembly Status 11.2004 ____________________________________________________________________________________________________________ _______________________________________________________________________________________ Knauf PFT GmbH & Co. KG Telephone 09323 / 31-760 PO Box 60 09323 / 31-770 D-97343 Iphofen Internet www.pft.de _______________________________________________________________________________________...
  • Page 19 ____________________________________________________________________________________________________________ PFT HM 6 FU 230V HYMIX Spare parts list – drive motor assembly Status 11.2004 ____________________________________________________________________________________________________________ Pos. Pcs. Article no. Article description 20 54 57 01 Drive pin jaw HM3 / HM5 25mm hole mi 20 20 96 03 Threaded pin with hexagon screw M8 x 20 DIN 916 20 54 57 02 Sealing ring –...
  • Page 20 ____________________________________________________________________________________________________________ PFT HM 6 FU 230V HYMIX Spare parts list – mixing tube assembly Status 11.2004 ____________________________________________________________________________________________________________ _______________________________________________________________________________________ Knauf PFT GmbH & Co. KG Telephone 09323 / 31-760 PO Box 60 09323 / 31-770 D-97343 Iphofen Internet www.pft.de _______________________________________________________________________________________...
  • Page 21 ____________________________________________________________________________________________________________ PFT HM 6 FU 230V HYMIX Spare parts list – mixing tube assembly Status 11.2004 ____________________________________________________________________________________________________________ Pos. Pcs. Article no. Article description 00 05 35 92 Allen screw M12 x 60 galvanised 00 05 62 88 Shaft adapter for rubber external bearing...
  • Page 22 ____________________________________________________________________________________________________________ PFT HM 6 FU 230V HYMIX Spare parts list – switch cabinet assembly Status 11.2004 ____________________________________________________________________________________________________________ _______________________________________________________________________________________ Knauf PFT GmbH & Co. KG Telephone 09323 / 31-760 PO Box 60 09323 / 31-770 D-97343 Iphofen Internet www.pft.de _______________________________________________________________________________________...
  • Page 23 ____________________________________________________________________________________________________________ PFT HM 6 FU 230V HYMIX Spare parts list – switch cabinet assembly Status 11.2004 ____________________________________________________________________________________________________________ Pos. Pcs. Article no. Article description 00 05 80 90 Fitting rack RAL2004 HM 6 20 20 17 00 Sealing for totally enclosed coupling 20 15 20 03 Dust collector filter –...
  • Page 24 ____________________________________________________________________________________________________________ PFT HM 6 FU 230V HYMIX Spare parts list – switch cabinet assembly Status 11.2004 ____________________________________________________________________________________________________________ _______________________________________________________________________________________ Knauf PFT GmbH & Co. KG Telephone 09323 / 31-760 PO Box 60 09323 / 31-770 D-97343 Iphofen Internet www.pft.de _______________________________________________________________________________________...
  • Page 25 ____________________________________________________________________________________________________________ PFT HM 6 FU 230V HYMIX Spare parts list – switch cabinet assembly Status 11.2004 ____________________________________________________________________________________________________________ Pos. Pcs. Article no. Article description 00 05 35 30 Empty housing HM 6 FU 230 Hymix RAL7032/Struk 00 02 21 74 Control transformer 230V/400V-42V 70VA without fuses 00 02 26 48 Frequency converter 230V 4KW 17.6A TYPE: CI...
  • Page 26: Technical Data

    ____________________________________________________________________________________________________________ PFT HM 6 FU 230V HYMIX Technical data Status 11.2004 ____________________________________________________________________________________________________________ Drive Drive motor 4 kW, 230 V, 50 Hz, three phase Current consumption 6.35 A Number of revolutions 280 min Dims. Length of everything 2005 mm Width of everything...