When operated correctly and with careful treatment, the PFT HM 6 will be a true assistant.
Page 3
Status 11.2004 ____________________________________________________________________________________________________________ Initial inspection after delivery An indispensable task of all fitters who deliver the PFT HM 6 is to check the machine settings after the initial starting up. The plant settings can change during the initial starting. If these are not corrected in good time, immediately after the warming up, there is a risk of breakdowns.
____________________________________________________________________________________________________________ PFT HM 6 FU 230V HYMIX Contents Stand 11.2004 ____________________________________________________________________________________________________________ General ................................1 List of contents..............................3 Overview................................4 Operating and display elements .........................5 Basic safety notices ............................6 Setting values ..............................8 Check list ................................10 Cleaning & measures upon completion of work....................12 Measures in the event of a power failure and danger of frost ................13 Transportation..............................13...
_______________________________________________________________________________________________________________ PFT HM 6 FU 230V HYMIX Basic safety notices Status 11.2004 _______________________________________________________________________________________________________________ HM 6 The PFT is a horizontal continuous mixer for factory-style pre-mixed mortar. It has been designed solely for silo operation. Please observe the material manufacturer’s processing guidelines.
Page 8
____________________________________________________________________________________________________________ PFT HM 6 FU 230V HYMIX Basic safety notices Status 11.2004 ____________________________________________________________________________________________________________ All safety and danger information on the machine must be observed and kept in a read- able state! The machine must be checked for any external damage and faults at least once per shift!
In accordance with VDE conditions, connect the machine only to an assembly for con- struction site (with stipulated FI safety switch). Use power cable 5x2.5mm² with CEE coupling 400 V, 3x16A PFT article number 20 42 33 50. Connect a mixer motor.
Page 10
Setting values and starting up Status 11.2004 ____________________________________________________________________________________________________________ After the horizontal mixer PFT HM 6 has been completely fitted and connected, the following procedure must take place: Open the silo flap. Switch on the PFT HM 6 using the green ON switch.
_______________________________________________________________________________________________________________ PFT HM 6 FU 230V HYMIX Checklist Status 11.2004 _______________________________________________________________________________________________________________ How can problems with the PFT HM 6 be avoided or quickly remedied? Problem Possible cause Remedy Machine won’t start up! Power - Is the power supply in order? Inspect the fault and remedy.
Page 12
_______________________________________________________________________________________________________________ PFT HM 6 FU 230V HYMIX Checklist Status 11.2004 _______________________________________________________________________________________________________________ - Metering and / or mixing shaft is / are blocked. - Too long or too weak power cable. - Too little material in the material con- tainer. _______________________________________________________________________________________ Knauf PFT GmbH &...
Maintenance and assembly work may only be carried out when the machine is without power (interrupt the power supply). Cleaning With a consistent daily operation, the PFT HM 6 needs only to be cleaned at the end of work. The cleaning is carried out in 5 stages 1.
PFT HM 6 shall again mix normally. Measures in the event of a danger of frost In the event of a danger of frost, the water fitting of the PFT HM 6 must be emptied. To do this:...
____________________________________________________________________________________________________________ PFT HM 6 FU 230V HYMIX Spare parts lists Status 11.2004 ____________________________________________________________________________________________________________ Spare parts list – drive motor assembly ......................17 Spare parts list – mixing tube assembly......................19 Spare parts list – water fitting assembly......................21 Spare parts list – switch cabinet assembly.......................23 _______________________________________________________________________________________ Knauf PFT GmbH &...
Page 18
____________________________________________________________________________________________________________ PFT HM 6 FU 230V HYMIX Spare parts list – drive motor assembly Status 11.2004 ____________________________________________________________________________________________________________ _______________________________________________________________________________________ Knauf PFT GmbH & Co. KG Telephone 09323 / 31-760 PO Box 60 09323 / 31-770 D-97343 Iphofen Internet www.pft.de _______________________________________________________________________________________...
Page 19
____________________________________________________________________________________________________________ PFT HM 6 FU 230V HYMIX Spare parts list – drive motor assembly Status 11.2004 ____________________________________________________________________________________________________________ Pos. Pcs. Article no. Article description 20 54 57 01 Drive pin jaw HM3 / HM5 25mm hole mi 20 20 96 03 Threaded pin with hexagon screw M8 x 20 DIN 916 20 54 57 02 Sealing ring –...
Page 20
____________________________________________________________________________________________________________ PFT HM 6 FU 230V HYMIX Spare parts list – mixing tube assembly Status 11.2004 ____________________________________________________________________________________________________________ _______________________________________________________________________________________ Knauf PFT GmbH & Co. KG Telephone 09323 / 31-760 PO Box 60 09323 / 31-770 D-97343 Iphofen Internet www.pft.de _______________________________________________________________________________________...
Page 21
____________________________________________________________________________________________________________ PFT HM 6 FU 230V HYMIX Spare parts list – mixing tube assembly Status 11.2004 ____________________________________________________________________________________________________________ Pos. Pcs. Article no. Article description 00 05 35 92 Allen screw M12 x 60 galvanised 00 05 62 88 Shaft adapter for rubber external bearing...
Page 22
____________________________________________________________________________________________________________ PFT HM 6 FU 230V HYMIX Spare parts list – switch cabinet assembly Status 11.2004 ____________________________________________________________________________________________________________ _______________________________________________________________________________________ Knauf PFT GmbH & Co. KG Telephone 09323 / 31-760 PO Box 60 09323 / 31-770 D-97343 Iphofen Internet www.pft.de _______________________________________________________________________________________...
____________________________________________________________________________________________________________ PFT HM 6 FU 230V HYMIX Technical data Status 11.2004 ____________________________________________________________________________________________________________ Drive Drive motor 4 kW, 230 V, 50 Hz, three phase Current consumption 6.35 A Number of revolutions 280 min Dims. Length of everything 2005 mm Width of everything...
Page 27
____________________________________________________________________________________________________________ PFT HM 6 FU 230V HYMIX Technical data Status 11.2004 ____________________________________________________________________________________________________________...
Page 28
WE KEEP THINGS MOVING Knauf PFT GmbH & Co. KG Postfach 60 D-97343 Iphofen Einersheimer Straße 53 D-97346 Iphofen Telephone 0 93 23/31-760 0 93 23/31-770 Email info@pft-iphofen.de...
Need help?
Do you have a question about the HM 6 FU 230V HYMIX and is the answer not in the manual?
Questions and answers