Troubleshooting; Specifications - Ventamatic QuFRESH AS1000WHT Owner's Manual

Table of Contents

Advertisement

FAULT
Unit does not
operate
Change light
illuminated
Blower wheel not
turning
WARNING:
DO NOT attempt to rectify faults using unqualified personnel.
If the problem you are experiencing is not listed here, call your
local distributor.
Power Supply:
Process Air:
MERV-9 Pre-Filter (inches):
Activated Carbon Filter (inches):
HEPA H-13 (inches):
Unit Size (inches):
Packing Size (inches):
Net/Gross Weight (lbs):
Complied:
Ventamatic, Ltd.
P.O. Box 728, Mineral Wells, TX 76068-0728

TROUBLESHOOTING

CAUSE
No power to machine
Switch not turned on
No power to outlet
GFCI tripped
Primary filter is full
Air intake restricted
Obstructed blower
Loose blower wheel
set screw

SPECIFICATIONS

SOLUTION
Plug in the unit; check
power at outlet
Turn on the switch
Reset circuit breaker/GFCI
Reset circuit breaker/GFCI
Replace the filters; refer to
maintenance section
Remove any obstructions
to airflow intake
Remove obstruction
Tighten set screw
115V / 60Hz / 210W 1.8A
MAX 500 CFM
16 x 16 x 1
16 x 16 x 1
16 x 16 x 2
25.5 x 16.5 x 22.625
26 x 17 x 22.875
46/51
cETLus
1-800-433-1626
Fax: 940.325.9311
WARNING
www.BVC.com