Smartphone operated controller for automatic self-cleaning filters (22 pages)
Summary of Contents for amiad ADI-X IOM
Page 1
NOTE: This document contains Amiad confidential information. Copying and distributing this document are strictly prohibited.
Page 2
Amiad or consult Amiad experts or its authorized representatives if you have any questions. Amiad Water Systems Ltd. D.N. Galil Elyon 1, 1233500, Israel Tel: 972 4 690 9500 | Fax: 972 4 814 1159 Email: info@amiad.com Amiad Water Systems - ADI-X IOM 910101-001180 / 06.2021...
Alerts Screen ............................. 52 4.4.3.4 Sites Manager Screen ..........................53 4.4.3.5 Localization Settings Screen ........................54 4.4.3.6 Support Screen ............................54 4.4.3.7 User Manual Screen ..........................55 4.4.3.8 Profile Screen ............................55 Amiad Water Systems - ADI-X IOM 910101-001180 / 06.2021...
Page 4
......................81 3 3 T 3 3 T 3 3 T 3 3 T A miad Limited Warranty .......................... 82 3 3 T 3 3 T 3 3 T 3 3 T Amiad Water Systems - ADI-X IOM 910101-001180 / 06.2021...
Page 5
F igure 35: ADI-X mobile application. Controller identification .............. 30 3 3 T U U 3 3 T F igure 36: ADI-X mobile application. Site ID screen ................31 3 3 T U U 3 3 T Amiad Water Systems - ADI-X IOM 910101-001180 / 06.2021...
Page 6
F igure 68: ADI-BLE mobile application Export Data................75 3 3 T U U 3 3 T F igure 69: ADI-X controllers chaining ..................... 76 3 3 T U U 3 3 T Amiad Water Systems - ADI-X IOM 910101-001180 / 06.2021...
Your ADI-X controller is equipped with a built-in feature that detects low temperatures and increases the number of flushes to avoid freezing of water. You can activate and adjust the settings of this feature in your Settings menu. Amiad Water Systems - ADI-X IOM 910101-001180 / 06.2021...
2 Introduction 2.1 About the ADI-X Controller ADI-X by Amiad, is our most advanced smart controller for a wide range of filtration solutions. By using the ADI-X, you will be able to receive real time data regarding your filter performance, relevant alerts, technical and marketing updates.
1. Disconnect all cables and pipes (see 3.3 ADI-X Terminal Blocks Connections and 3.4 ADI-X DP Sensor Connections). 2. Push the controller up to remove it from the bracket. Bracket Back view Figure 3: Removing the ADI-X controller from the bracket Amiad Water Systems - ADI-X IOM 910101-001180 / 06.2021...
3. Tighten the bracket to the plate using 4 screws. Plate Bracket Figure 4: Bracket installation on plate 4. Attach the controller to the bracket. Press the controller until you hear “click”. Notice: handle with care Amiad Water Systems - ADI-X IOM 910101-001180 / 06.2021...
5. Using a drill, install 4 wall anchors in the marked locations. Attach the bracket to the wall. Tighten the mounting screws into the anchors. Wall Bracket Figure 5: Bracket installation on wall 5. Attach the controller to the bracket. Press the controller until you hear “click”. Amiad Water Systems - ADI-X IOM 910101-001180 / 06.2021...
Alarm output: Used to switch external device via NO/NC relay. End of cycle (EOC): Used to send EOC signal via NO/NC relay. External power supply connection. Power supply for the controller must supply 7-14 VDC, 2A. Amiad Water Systems - ADI-X IOM 910101-001180 / 06.2021...
Page 14
Notice: every external device connected to the controller should be correctly set up in controller settings (see 5.3). For example: number of filtration units must be specified correctly; type of analog device connected to the controller must be specified in corresponding field. Amiad Water Systems - ADI-X IOM 910101-001180 / 06.2021...
The controller’s default configuration is the internal DP sensor. Water pipes should be connected to the DP inlet and outlet (See Figure 1: ADI-X controller components). Water connection Water connection Figure 9: Internal DP sensor connections Amiad Water Systems - ADI-X IOM 910101-001180 / 06.2021...
1. Remove the top cover by loosening the four screws. Figure 10: ADI-X controller Top cover removal 2. Remove the two screws that secure the battery cover. This will allow access to the battery assembly. Figure 11: Battery cover removal Amiad Water Systems - ADI-X IOM 910101-001180 / 06.2021...
Page 17
Figure 12: Battery assembly with 4 x 1.5V D batteries 4. Reinstall the battery assembly. 5. Close battery cover and tighten the screws. 6. Reassemble the top cover and tighten the screws. Amiad Water Systems - ADI-X IOM 910101-001180 / 06.2021...
The free ADI-X and ADI-BLE mobile applications by Amiad Water Systems are available for download on Google Play (Android version 5 and up) or the App Store (iOS version 9 and up).
Page 19
A verification code will be sent to your email. Log into your email account, open the mail and copy your verification code. Paste the verification code and click "Verify code". Figure 15: ADI-X Desktop application Sign Up Screen 2 Amiad Water Systems - ADI-X IOM 910101-001180 / 06.2021...
Page 20
"Confirm New Password" field. Remember your password! Click "Create". Figure 16: ADI-X Desktop application Sign Up Screen 3 Enter your Full Name, Country, Company and Job Description. Click "Next". Figure 17: ADI-X Desktop application Sign Up Screen 4 Amiad Water Systems - ADI-X IOM 910101-001180 / 06.2021...
Page 21
Select your application language and units (METRIC or IMPERIAL). Click "SUBMIT". Figure 18: ADI-X Desktop application Sign Up Screen 5 Your ADI-X user account was created! Figure 19: ADI-X Desktop application. Home page Amiad Water Systems - ADI-X IOM 910101-001180 / 06.2021...
Figure 20: ADI-X mobile application. Sign in Screen 1 2. Enter your password (created during sign up in ADI-X Desktop application). Click "SUBMIT". Figure 21: ADI-X mobile application. Sign in Screen 2 Amiad Water Systems - ADI-X IOM 910101-001180 / 06.2021...
2. Click "OK" to start setting up your account. Figure 22: ADI-BLE mobile application. Welcome screen. 3. Select your preferred system units (Metric or Imperial and click "OK". Figure 23: ADI-BLE mobile application. System units screen. Amiad Water Systems - ADI-X IOM 910101-001180 / 06.2021...
Page 24
Figure 24: ADI-BLE mobile application. Registration screen. 5. At this stage, your account was successfully created and is ready use. Figure 25: ADI-BLE mobile application. Account creation confirmation. Amiad Water Systems - ADI-X IOM 910101-001180 / 06.2021...
2. If needed, Press the Left Button to enable LED backlight. 3. Press and hold the Left Button on the ADI-X controller until the 8-digit PIN code appears on the screen. Left button Figure 26: ADI-X controller in communication mode Amiad Water Systems - ADI-X IOM 910101-001180 / 06.2021...
"ADD SITE". Figure 27: ADI-X Desktop application. The first site adding on Home screen. Figure 28: ADI-X Desktop application. New sites adding on Sites manager screen. Amiad Water Systems - ADI-X IOM 910101-001180 / 06.2021...
Page 27
4. In “Site ID" window, fill in the "Name Your Site" field, select a Filter Model from the list, enter filter serial number in "Filter Serial Number" field, add site picture by clicking "Add site image". Click "NEXT". Figure 30: ADI-X Desktop application. Site ID window. Amiad Water Systems - ADI-X IOM 910101-001180 / 06.2021...
Page 28
Figure 31: ADI-X Desktop application. Site information window. 6. In “Site Location” window set the location of the site on the map. Click "SUBMIT". Figure 32: ADI-X Desktop application. Site location window. Amiad Water Systems - ADI-X IOM 910101-001180 / 06.2021...
Page 29
8. In “Site Added” window your ADI-X is ready to use. Click “Continue”. 9. To view data from your controller, select the desired controller from “Sites List” on Sites page (see 4.3.3.2). Amiad Water Systems - ADI-X IOM 910101-001180 / 06.2021...
Figure 33: ADI-X mobile application. Add site 3. Make sure the controller is turned on and in communication mode. Enter the 8-digit PIN code obtained from the controller. Click "NEXT". Figure 34: ADI-X mobile application. Controller identification Amiad Water Systems - ADI-X IOM 910101-001180 / 06.2021...
Page 31
5. In “Site Information” screen select water source from the list, enter flow rate in "Flow Rate /h)" field, enter working pressure in "Working Pressure (BAR)" field, select filtration degree from the list. Click "NEXT". Figure 36: ADI-X mobile application. Site information screen Amiad Water Systems - ADI-X IOM 910101-001180 / 06.2021...
Page 32
7. In “Payment” window you should confirm the payment notice. At this stage, your controller is connected to your account and ready for use! Click “Next”. Figure 38: ADI-X mobile application. Payment Notice screen Amiad Water Systems - ADI-X IOM 910101-001180 / 06.2021...
Page 33
8. At this stage your controller was connected to your user account and ready for use! Click "SUBMIT". Figure 39: ADI-X mobile application. Site location screen 9. To view data from your controller, select the desired controller from “Sites List” on Sites screen (see 4.4.3.1). Amiad Water Systems - ADI-X IOM 910101-001180 / 06.2021...
4.2.3 Pairing ADI-X Controller using the ADI-BLE Mobile Application Notice: Pairing the ADI-X controller with the Bluetooth® application will utilize part of the full list of features available in the cloud applications. Amiad recommends pairing the ADI-X controller with the dedicated ADI-X applications (Mobile and Desktop).
Page 35
2. Select your controller from the controllers list in range. The application will start pairing. Figure 41: ADI-BLE mobile application. Scan screen. 3. Verify that the blue/green LED on your controller is blinking. Click "YES" to confirm. Figure 422: ADI-BLE mobile application. Confirm pairing screen. Amiad Water Systems - ADI-X IOM 910101-001180 / 06.2021...
Page 36
Figure 433: ADI-BLE mobile application. Site ID screen. 5. Enter the Site Information details (optional), Click "SUBMIT" to add your new filter to the Sites List. Figure 444: ADI-BLE mobile application. Site Information screen. Amiad Water Systems - ADI-X IOM 910101-001180 / 06.2021...
Page 37
6. To view data from your controller, select the active controller from the “Sites List”, marked by the active Bluetooth® icon. Figure 455: ADI-BLE mobile application. Site data. Amiad Water Systems - ADI-X IOM 910101-001180 / 06.2021...
Information – The Support contains a message pop-up window. See 04.3.3.7. Support The User Manual contains a link to the digital version of the User Manual. See Information – User Manual 4.3.3.8. Amiad Water Systems - ADI-X IOM 910101-001180 / 06.2021...
Home page is displayed after log in. You can return to Home page by clicking “Home” in the Header line or by clicking on the ADI-X logo in the upper left corner. The Home page contains the Sites List and Notification center. Amiad Water Systems - ADI-X IOM 910101-001180 / 06.2021...
Page 40
Allows selecting which notifications are shown – all / alerts / flushes / invitations. Each element of the list contains following information: List of notifications • Notification text • The name of controller where notification appeared Amiad Water Systems - ADI-X IOM 910101-001180 / 06.2021...
The controller connection mode – online or offline. Last connection Only in offline mode. The last time the controller was connected. Next connection Only in offline mode. The time of next attempt to connect to the controller. Amiad Water Systems - ADI-X IOM 910101-001180 / 06.2021...
Page 42
Following information for every flush is shown: • Flush cause • Flush date List of flushes • Flush time • Inlet pressure before the flush • Outlet pressure before the flush • DP pressure before the flush Amiad Water Systems - ADI-X IOM 910101-001180 / 06.2021...
Page 43
4.3.3.2.8 Settings tab This tab contains controller settings. See the list of settings with description in Appendix A. ADI-X Controller Settings. Click the setting to change it. Click "Save" to save changes. Amiad Water Systems - ADI-X IOM 910101-001180 / 06.2021...
Display the active alerts or the list of alert messages according to their occurrence Alerts list time and date (Active/History tab). See Appendix B. Alarms and Faults List. Page navigation Use arrows in bottom left corner to switch between pages. Amiad Water Systems - ADI-X IOM 910101-001180 / 06.2021...
List of linked sites. Each element of the list contains the following information: • Site picture • Communication status icon Linked Sites List • Site name • Filter type • Delete icon – click this icon to delete the site from the account. Amiad Water Systems - ADI-X IOM 910101-001180 / 06.2021...
The language of applications (drop-down list). Units selection Units to be used in applications. Receive updates Check this checkbox to receive updates from Amiad. from Amiad Save button Click Save to save any changes. Amiad Water Systems - ADI-X IOM...
4.3.3.7 Support Pop-Up Window Support Pop-Up Window allows sending messages to Amiad support. It contains the following elements: Element Description Full name Your full name Email Your email Company Your company name Message field Write your message to Amiad support here.
See 4.4.3.7. Account – Profile The Profile screen contains the user account information. See 4.4.3.8. Account – Sign out The Sign out screen allows the user to sign out of the account. Amiad Water Systems - ADI-X IOM 910101-001180 / 06.2021...
Only in offline mode. The time of next attempt to connect to the controller. Only in offline mode. Indicates if controller configuration is up to date (last Conf. Params changes synchronized with controller) – Synced / Not synced Amiad Water Systems - ADI-X IOM 910101-001180 / 06.2021...
Page 50
The pressure differential across the filter; calculated by subtracting the outlet Pressures – DP pressure from the inlet pressure. Manual Flushing button Only in online mode. Click this button to start a manual flush cycle. Amiad Water Systems - ADI-X IOM 910101-001180 / 06.2021...
Page 51
Outlet pressure before the flush • • DP pressure before the flush • DP pressure after (the DP measured after flushing. Interval between end of flushing and DP measuring is determined by "Ignore DP" parameter). Amiad Water Systems - ADI-X IOM 910101-001180 / 06.2021...
4.4.3.3 Alerts Screen The Alerts screen contains active alerts from all connected controllers and a list of alert messages according to their occurrence time and date. Amiad Water Systems - ADI-X IOM 910101-001180 / 06.2021...
Communication status icon • Linked Sites list Power mode icon • Site name • • Site owner email • Delete icon – click this icon to delete the site from the account. Amiad Water Systems - ADI-X IOM 910101-001180 / 06.2021...
Units selection Units to be used in applications. SUBMIT button Click SUBMIT to save any changes. 4.4.3.6 Support Screen Support Screen allows sending messages to Amiad support. It contains the following elements: Element Description Full name Your full name Email...
Company User’s company name. Job description User’s job description (drop-down list). Receive updates Check this checkbox to receive updates from Amiad. from Amiad SUBMIT button Click SUBMIT to save any changes done. Amiad Water Systems - ADI-X IOM 910101-001180 / 06.2021...
List of all paired sites. Clicking on active site will open Site tabs (see 4.5.1.3). Each element of the list contains following information: • Site picture • Site name • Bluetooth® icon – blue when available and grey when out of range Amiad Water Systems - ADI-X IOM 910101-001180 / 06.2021...
Displays the registration details of the system: User name, User email, User country, User company and User job description. User Manual This screen shows the user manual. Support Contact Us screen. App Version Displays the current version of the ADI-BLE Application. Amiad Water Systems - ADI-X IOM 910101-001180 / 06.2021...
The number of flush cycles started due to a manual start command issued by the user. Total Flushing Cycles The total number of flush cycles started for any reason. Reset Button Click this button to reset the counters to zero. Amiad Water Systems - ADI-X IOM 910101-001180 / 06.2021...
Page 59
" icon in the upper right corner of any of the 5 tabs. This menu contains controller settings. See the list of settings with description in Appendix A. ADI-X Controller Settings. Click the setting to change it. Click "Save" to save changes. Amiad Water Systems - ADI-X IOM 910101-001180 / 06.2021...
2. Go to "Sites manager" screen in the left menu and choose with site to share. 3. Click the "Invite" icon on the site you want to share. Figure 46: ADI-X Desktop application. Sites Manager screen Amiad Water Systems - ADI-X IOM 910101-001180 / 06.2021...
Page 61
5. An invitation notification will appear in the Notifications Center. Click "ACCEPT" to accept the invitation. The site will appear in the linked sites list. Figure 48: ADI-X Desktop application. Home page, accept invitation Amiad Water Systems - ADI-X IOM 910101-001180 / 06.2021...
Page 62
5. In the account you shared with an invitation notification will appear on the "Sites Manager" screen. Click "ACCEPT" to accept the invitation. The site will appear in the list of linked sites. Figure 50: ADI-X mobile application. Accept invitation Amiad Water Systems - ADI-X IOM 910101-001180 / 06.2021...
Notice: Do not change any of these settings if you are not fully familiar with the specific filtration system, filter type, and controller. Incorrect settings may lead to nonoperational system. 5. Make sure to click “Save” after changing any of the settings. Amiad Water Systems - ADI-X IOM 910101-001180 / 06.2021...
Page 64
Notice: Do not change any of these settings if you are not fully familiar with the specific filtration system, filter type, and controller. Incorrect settings may lead to nonoperational system. Make sure to click “Save” after changing any of the settings. Amiad Water Systems - ADI-X IOM 910101-001180 / 06.2021...
Page 65
Notice: Do not change any of these settings if you are not fully familiar with the specific filtration system, filter type, and controller. Incorrect settings may lead to nonoperational system. Make sure to click “Save” after changing any of the settings. Amiad Water Systems - ADI-X IOM 910101-001180 / 06.2021...
Settings" (see options above). Figure 54: ADI-X Desktop application. Sites screen, Settings tab 4. Click "OK" in the dialog window to approve the settings restoration. Figure 55: ADI-X Desktop application. Dialog windows Amiad Water Systems - ADI-X IOM 910101-001180 / 06.2021...
Page 67
4. Click "Restore to Filter Type Settings" or "Restore to Factory Settings" (see options above). Figure 56: ADI-X mobile application. Settings menu 5. Click "OK" in the dialog window to approve the settings restoration. Figure 57: ADI-X mobile application. Dialog windows Amiad Water Systems - ADI-X IOM 910101-001180 / 06.2021...
Page 68
4. Click "Restore to Filter Type Settings" or "Restore to Factory Settings" (see options above). Figure 58: ADI-BLE mobile application. Settings menu 5. Click "OK" in the dialog window to approve the settings restoration. Figure 59: ADI-BLE mobile application. Dialog windows Amiad Water Systems - ADI-X IOM 910101-001180 / 06.2021...
2. Go to "Sites" tab in left menu and select the required site. 3. Go to "Overview" tab and click "Reset" in the Flushing Cycles field. The counters will reset. Figure 60: ADI-X Desktop application. Sites screen, Overview tab Amiad Water Systems - ADI-X IOM 910101-001180 / 06.2021...
Page 70
2. On "Sites" screen select the site where you want to reset counters. 3. Go to "Counters" tab. 4. Click "Reset" in the middle of the screen. The counters will reset. Figure 61: ADI-X mobile application. Sites screen, Counters tab Amiad Water Systems - ADI-X IOM 910101-001180 / 06.2021...
Page 71
(Bluetooth® icon is blue). 2. Select the required site. 3. Go to "Counters" tab. 4. Click "Reset" in the middle of the screen. The counters will reset. Figure 62: ADI-BLE mobile application. Counters screen Amiad Water Systems - ADI-X IOM 910101-001180 / 06.2021...
1. Open the ADI-X protection cover. 2. If needed, Press the left button to enable LED backlight. 3. Press the right button (short press). The flushing will start. Right button Figure 63: ADI-X controller control panel Amiad Water Systems - ADI-X IOM 910101-001180 / 06.2021...
Page 73
2. On "Sites" screen select the site you want to initiate manual flushing. 3. On "Online Status" tab select "Manual Flushing". The flushing will start. Figure 65: ADI-X mobile application. Sites screen, Online status tab Amiad Water Systems - ADI-X IOM 910101-001180 / 06.2021...
Page 74
(Bluetooth® icon is blue). 2. Select the site you want to initiate manual flushing. 3. On "Online Status" tab select "Manual Flushing". The flushing will start. Figure 66: ADI-BLE mobile application. Online status screen Amiad Water Systems - ADI-X IOM 910101-001180 / 06.2021...
Select the preferred application, the recipient, and send the reports. 5. ADI-BLE Mobile application sends 5 reports in CVS (Excel file format): system-id, parameters- setup, flush-events, alarm-events, and params-setup-audit. Amiad Water Systems - ADI-X IOM 910101-001180 / 06.2021...
2. Set the primary controller Operation mode to "Primary" and select the number of the secondary controllers (for primary controller settings - see 5.3). 3. Set the secondary controllers Operation mode to "Secondary" (see 5.3). Amiad Water Systems - ADI-X IOM 910101-001180 / 06.2021...
Allows the user to delete all the controller’s data and restore the factory default Settings settings; The default filter model will be according to the filter provided with the controller, or according to the customer's initial settings. Amiad Water Systems - ADI-X IOM 910101-001180 / 06.2021...
Notice: Do not change any of these settings if you are not fully familiar with the specific filtration system, filter type, and controller. Incorrect settings may lead to nonoperational system. Access to the Technician Settings requires a 4-digit code: “1234”. Amiad Water Systems - ADI-X IOM 910101-001180 / 06.2021...
Page 79
2 and finishes at 1 • next starts at 3 and finishes at 2 • next starts at 4 and finishes at 3 • and so on. Amiad Water Systems - ADI-X IOM 910101-001180 / 06.2021...
Page 80
Lower value (4 mA / 0 volt) – Set the lower value. Higher value (20 mA / 10 volt) – Set the higher value. Sensor Type (Pressure, Temperature, Conductivity, Turbidity, Humidity). Units (BAR/PSI, Celsius/Fahrenheit, S/m, NTU, %). Default value: BAR. Amiad Water Systems - ADI-X IOM 910101-001180 / 06.2021...
Adjust the water system inlet pressure pressure maximum allowed pressure for the filter Anti-Freeze Active Freezing Protection start, as a result of Low Temperature Threshold Anti-Freeze Exit Stop Freezing Protection procedure Amiad Water Systems - ADI-X IOM 910101-001180 / 06.2021...
In no event shall Amiad be liable to the Buyer or any third party for any damages to property, or for any intangible or economic loss, including loss of profits, loss of customers or damage to reputation, for any damages, including indirect, special, consequential damages, or punitive damage arising out of or in connection with this Warranty, or arising out of or in connection with the product's performance or failure to perform, even if it has been advised of the possibility of such damages.
Page 83
Bluetooth SIG, Inc. and any use of such ® marks by Amiad Water Systems is under license. Other trademarks and trade names are those of their respective owners. Amiad Water Systems - ADI-X IOM...
Need help?
Do you have a question about the ADI-X IOM and is the answer not in the manual?