Idex MICROPUMP 668-400-2 Component Maintenance Manual With Illustrated Parts List page 13

Pressurematic water system
Table of Contents

Advertisement

2.2 Electrical Requirements
2.2.1 A 200 V ac, 400 Hz. 3 phase (115 V ac phase-to-neutral) power source capable
of delivering 1 amp continuously, which is needed to operate the pump motor.
2.3 Test Setup
2.3.1 The test setup shown in Figure C, or its equivalent, is required to check the
operating condition and adjust the Model 668-400-2. Required electrical
connections are described in Figure D.
2.4 Adjustment/Test Procedures
2.4.1 Adjustments
2.4.1.1 Over-Pressure Release Adjustment
2.4.1.1.1 This adjustment prevents back flow up to 30 psi (2.07 bar) system
2.4.1.1.2 Connect Model 668-400-2 into test set. Close valves 1 and 2. Add
2.4.1.1.3 Adjustment involves removal or addition of shims in over-pressure
2.4.1.1.4 After adjustment, remove hand pump from test setup and
2.4.1.2 Pressure Regulator Adjustment
2.4.1.2.1 This adjustment prevents the pump from increasing system
PO Box 8975, Vancouver, WA 98668-8975 • Phone: 360/253-2008 • Fax: 360/253-8294
2 Howard Road, Eaton Socon, St.
pressure.
one hand pump to test setup between pressure gauge and valve 2.
Open valve 1 completely and valve 2 partially. Energize pump and
run for one minute to establish water in test system. De-energize
pump. Close valves 1 and 2. Disconnect tubing from valve 1
(pump side). Establish system pressure with hand pump, allowing
pressure to build slowly to 25 psi (1.73 bar). Watch tubing
disconnected from valve 1 and raise system pressure slowly toward
30 psi (2.07 bar). Water should start to leak from tubing at 30 psi
(2.07 bar).
release setting and requires disassembly of that setting. Refer to
Disassembly and Figure 2 of IPL. One shim approximately equals
3 psi (.21 bar). Add shim (s) to raise setting; remove shim(s) to
lower setting.
reconnect tubing to valve 1.
pressure above 25 psi (1.72 bar) while in operation.
MICROPUMP, INC.
A Unit of IDEX Corporation
MICROPUMP
A Subsidiary of Micropump, Inc.
Neots, Cambridgeshire, PE 19 8ET England, • Phone: 011-44-1480-356600 • Fax: 011-44-
Page 13 of 33
LIMITED
356300
1480-

Advertisement

Table of Contents
loading

This manual is also suitable for:

Micropump 8700

Table of Contents