◇Response
Command format : SVALUE□ sys , data
NOTE: This command is not executed unless the specified channel is in the CR mode.
Example: SVALUE? 1,1 ... Inquires about the STEP value of the channel A of PRESET 1.
SVALUE 1,30000 ... The STEP value of the unit of system address 1 is 30000.
10-2-11 Query about set current limit
Command name : CLIM?
Function
◇Query
Command format : CLIM? □ pre , ch
◇Response
Command format : CLIM□ sys , data
NOTE: This command is not executed if the specified channel is in the short circuit mode or CC
mode.
Example: CLIM? 1,1 ... Inquires about the set current limit of the channel A of PRESET 1.
10-2-12 Query about switching select status
Command name : SWSEL?
Function
◇Query
Command format : SWSEL? □ ch
◇Response
Command format : SWSEL□ sys , flg
Example: SWSEL? 1 ... Inquires about the switching select status of the channel A.
SWSEL 1,0 ... Switching select of the unit of system address 1 is turned off.
sys : System address 1 to 32
data : STEP value in CR mode
Integer data between 3 and 30000. A maximum of five characters.
: Inquires about the set current limit.
pre : PRESET key
1: PRESET 1 key, 2 : PRESET 2 key, 3: PRESET 3 key, 4: PRESET 4 key
ch : Channel
1: Channel A, 2: Channel B, 3: Channel C, 4: Channel D
sys : System address 1 to 32
data : Set current limit
Real data in units of A. A maximum of six characters (including the decimal
point).
CLIM 1,15.0 ... The set current limit of the unit of system address 1 is 15.0 A.
: Inquires about the switching select status.
ch : Channel
1: Channel A, 2: Channel B, 3: Channel C, 4: Channel D
sys : System address 1 to 32
flg : Switching select status of the specified channel
0: Off, 1: On