Download Print this page
S&P PCD110 Quick Start Manual

S&P PCD110 Quick Start Manual

Ventilation fan

Advertisement

Quick Links

Model: PCD110
WARNING
WARNING -TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
a). Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer
b). Before servicing or cleaning unit, switch power off at service panel and lock the service disconnecting means to prevent power from being switching
on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.
c). Installation work and electrical wiring must be done by a qualified person(s) in accordance with all applicable codes and standards, including fire-rated
construction codes and standards.
d). Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to prevent backdrafting.
Follow the heating equipment manufacturer's guideline and safety standards such as those published by the National Fire Protection Association (NFPA),
and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities.
e). When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.
f). Ducted fans must always be vented to the outdoors.
g). Acceptable for use over a tub or shower when connected to a GFCI (Ground Fault Circuit Interrupter) - protected branch circuit (ceiling installation only).
h). This unit must be grounded.
i). Not for Use in Kitchens.
j). To reduce risk of fire and to properly exhaust air, be sure to duct air outside – Do not vent exhaust air into spaces within walls or ceilings or into attics,
crawl spaces, or garages
k). WARNING: To Reduce The Risk Of Fire Or Electric Shock, Do Not Use This Fan With Any Solid-State Speed Control Device.
l). The fan must not be installed in a ceiling thermally insulated to a value greater R40.
CAUTION
1. For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors.
2. This product is designed for installation in ceilings up to a 12/12 pitch (45 degree angle). Duct connector must point up.
3. To avoid motor bearing damage and noisy and/or unbalanced impellers, keep drywall spray, construction dust, etc. off power unit.
4. Please read specification label on product for further information and requirements.
*The manual in electronic format can be download in our company web, or obtained from our dealer.
CLEANING & MAINTENANCE
For quiet and efficient operation, long life, and attractive appearance - lower or remove grille and vacuum interior of unit with the dusting
brush attachment.
The motor is permanently lubricated and never needs oiling. If the motor bearings are making excessive or unusual noises, replace the
motor with the exact service motor. The impeller should also be replaced.
OPERATION
The control box, located inside the fan housing, has three separate adjustments:
(1) The low airflow knob adjusts the lower airflow from 30CFM up to the air flow
rate of the high fan speed determined by the toggle switch setting.
(2) (a)The time delay knob is adjustable from 3 to 30 minutes and will switch the
fan to the low speed setting after motion is no longer detected in the room for
the set period of time(for model PCD110).
(b)The humidity sensor knob set user-adjustable setpoint(for model PCD110H).
(3) The toggle switch will adjust the upper fan speed setting from 80 to 120 CFM
using a 4" duct, or 90 to 140 CFM using a 6" duct.
Both 4" & 6" duct adaptors are included.
For model PCD110
To Turn Fan ON
Turn the switch I ON.(according to the following "CONNECT ELECTRICAL WIRING")
• Fan will run at the certified airflow rate if the switch II is ON.
• Fan will run at the user-adjustable airflow rate if the switch II is OFF.
To Use Fan Time Delay Airflow Rate Change
1. Turn the switch I ON.
2. Turn the switch II ON - fan will run at the certified airflow rate.
3. When the switch II is turned OFF, fan will continue to run at the certified airflow
rate until the user-adjustable time delay has elapsed, and then will automatically
change to the user-adjustable airflow rate.
To Turn Fan OFF
Turn the switch I OFF
For model PCD110H
1) Fan run continuously at a low speed(adjustable by low airflow knob) and automatically boost up to high speed when either of these
conditions is detected: a)Humidity above a user-adjustable setpoint (50%-100% relative humidity). b) rapid to moderate (user-adjustable)
increases in humidity .After delay timer (20 minutes) returns fan to the default low speed.Humidity sensor description accroding to
"HUMIDITY SENSOR OPERATION" and"SENSITIVITY ADJUSTMENT".
2) When the switch is turned on, the fan will run at high speed. When the switch is turned OFF, fan will continue to run at the certified airflow
rate until the delay timer (20 minutes) has elapsed,and then will automatically change to the user-adjustable airflow rate.
PCD110H
READ AND SAVE THESE INSTRUCTIONS
Installer: Leave this manual with the homeowner.
VENTILATION FAN
Timer delay knob
(for model PCD110)
or
Humidity sensor knob
(for model PCD110H)
Low airflow
knob
-
-
+
+
Switch
position
1 2 3
1 2 3
1 2 3
1 2 3
1 2 3
1 2 3
Air deliver
80 90 110 120 90 110 120 140
(CFM)
Duct
4"
4"
4"
4"
6"
diameter
(inches)
Switch
position
1 2 3
1 2 3
1 2 3
1 2 3
Airflow
80 90 110 120 90 110 120 140
(CFM)
Duct
4"
4"
4"
4"
diameter
(inches)
is the position of switch
Factory setting: 110CFM (
with 6" duct
HVI Certified performance based on HVI Procedures 915, 916,
and 920.
Other airflow reference performance based on HVI Procedures
915, 916, and 920.
Power box
Toggle switch
1 2 3
1 2 3
1 2 3
1 2 3
1 2 3
1 2 3
1 2 3
1 2 3
6"
)

Advertisement

loading

Summary of Contents for S&P PCD110

  • Page 1 Toggle switch fan to the low speed setting after motion is no longer detected in the room for Low airflow the set period of time(for model PCD110). knob 1 2 3 (b)The humidity sensor knob set user-adjustable setpoint(for model PCD110H).
  • Page 2 OPERATION HUMIDITY SENSOR OPERATION The humidity-sensing fan uses a sophisticated humidity sensor that responds to: (a) rapid to moderate (user-adjustable) increases in humidity or (b) humidity above a user-adjustable set-point (50%-100% relative humidity). Fan run continuously at a pre-set lower level (set by Humidity sensor knob) and automatically boost up to certified airflow rate when environmental conditions change).
  • Page 3 Run 120 V AC house wiring to the location of the fan. Use only UL-approved connectors (not included) to attach the house wiring to the wiring plate. Refer to the wiring diagram, and connect the wires as shown. For model PCD110 BLACK (BLK)
  • Page 4 INSTALL GRILLE Install ceiling material to complete the ceiling construction. Then, cut around the fan housing. To attach the grille assembly to the fan housing, pinch the grille springs on the sides of the grille assembly, and position the grille into the housing with the grille springs in the appropriate slots.

This manual is also suitable for:

Pcd110h