Download Print this page

S&P PCD110 Quick Start Manual page 3

Ventilation fan

Advertisement

ASSEMBLY INSTRUCTIONS
2b. Extend the hanger bars to the width of the framing. Position the
ventilator with the hanger bar tabs wrapped around the bottom edge of
the framing, holding the ventilator in place.
Secure hanger bars to framing using one screw on each end of hanger bar.
Select a proper hole and secure the hanger bars together using flange
screws.
3. ATTACH DAMPER/DUCT CONNECTOR
Snap the damper/duct connector onto the fan housing. The connector
must be flush with the top of the housing, and the damper flap should
fall closed.
Insulated flexible duct is recommended for the quietest possible installation.
If rigid duct is used, a short (1-3 feet) section of insulated flexible duct will
ensure quiet operation
ASSEMBLY INSTRUCTIONS
4. INSTALL ROUND DUCTWORK
Connect the round ductwork (not included) to the damper/duct connector,
and run the ductwork to a roof or wall cap (not included). Using tape (not
included), secure all the ductwork connections so that they are air tight.
CONNECT ELECTRICAL WIRING
Run 120 V AC house wiring to the location of the fan. Use only UL-approved connectors (not included) to attach the house wiring to the
wiring plate. Refer to the wiring diagram, and connect the wires as shown.
For model PCD110
SWITCH I
SWITCH II
For model PCD110H
SWITCH
BRN
FAN
BLK
BRN
FAN
BLK
BLACK (BLK)
GROUND (GRD)
SWITCH I
SWITCH II
SWITCH BOX
POWER SUPPLY
120V AC
BLACK(BLK)
BROWN(BRN)
SWITCH
SWITCH BOX
120V AC LINE IN
3
NAIL
DUCT
WHITE (WHT)
BROWN (BRN)
WIRE
UNIT
PANEL
FAN
RECEPTACLE
WHITE (WHT)
GROUND (GRD)
WIRE PANEL
UNIT
RECEPTACLE
SCREW