Panasonic CU-J24DBE5 Service Manual page 112

Hide thumbs Also See for CU-J24DBE5:
Table of Contents

Advertisement

Ambient
Model
Power
Return
(CS-)
Source
D.B.
F43DB4E5
400V,
50Hz,
23
3 phase
25
27
29
32
F50DB4E5
400V,
50Hz,
23
3 phase
25
27
29
32
TC: Cooling Capacity
SHC: Sensible Heat Capacity
IPT: Cooling Power Consumption
25°C
Air
TC
SHC
IPT
W.B.
kW
kW
kW
17
13.01 8.52
3.81 12.50 8.44
19
13.74 7.01
4.04 13.31 7.06
22
15.01 5.40
4.36 14.60 5.55
17
12.86 9.84
3.82 12.36 9.70
19
13.76 8.67
4.06 13.28 8.63
22
15.00 6.82
4.39 14.54 6.91
17
12.70 11.30 3.82 12.22 11.12 4.12 11.53 10.72 4.48 10.72 10.29 4.87 10.14 10.04 5.16
19
13.78 10.19 4.09 13.25 10.07 4.40 12.50 9.75
22
14.99 8.24
4.41 14.48 8.25
17
12.67 12.42 3.80 12.22 12.10 4.11
19
13.75 11.68 4.06 13.25 11.53 4.39 12.50 11.13 4.73 11.72 10.72 5.08 11.14 10.47 5.30
22
14.93 9.78
4.47 14.42 9.73
17
12.66 12.40 3.78 12.22 12.22 4.10 10.69 10.69 4.39 10.86 10.86 4.68 10.35 10.35 4.82
19
13.73 13.59 4.04 13.25 13.25 4.39 12.51 12.51 4.70 11.78 11.78 5.00 11.23 11.23 5.15
22
14.89 12.21 4.51 14.38 12.08 4.90 13.62 11.71 5.24 12.78 11.37 5.58 12.18 11.08 5.75
17
14.05 9.21
4.12 13.50 9.11
19
14.84 7.57
4.37 14.38 7.62
22
16.21 5.83
4.72 15.77 5.99
17
13.89 10.62 4.13 13.35 10.48 4.46 12.58 10.12 4.86 11.66 9.74
19
14.86 9.36
4.39 14.34 9.32
22
16.20 7.37
4.75 15.71 7.46
17
13.72 12.21 4.13 13.19 12.01 4.45 12.45 11.58 4.85 11.58 11.11 5.27 10.95 10.84 5.58
19
14.88 11.01 4.42 14.31 10.88 4.76 13.50 10.53 5.18 12.56 10.17 5.63 11.88 9.86
22
16.19 8.90
4.77 15.64 8.92
17
13.69 13.41 4.11 13.20 13.06 4.44 12.42 12.42 4.79 11.67 11.67 5.14 11.09 11.09 5.36
19
14.85 12.62 4.39 14.31 12.45 4.75 13.51 12.02 5.12 12.65 11.58 5.50 12.03 11.30 5.73
22
16.12 10.56 4.84 15.57 10.51 5.23 14.73 10.23 5.64 13.79 9.93
17
13.67 13.39 4.09 13.20 13.20 4.44 11.55 11.55 4.75 11.73 11.73 5.06 11.18 11.18 5.21
19
14.82 14.68 4.37 14.31 14.31 4.74 13.51 13.51 5.08 12.72 12.72 5.41 12.12 12.12 5.57
22
16.08 13.18 4.88 15.53 13.04 5.29 14.71 12.65 5.67 13.80 12.28 6.03 13.15 11.97 6.22
Temperature Air Entering Condenser (°C D.B.)
30°C
35°C
TC
SHC
IPT
TC
SHC
kW
kW
kW
kW
kW
4.13 11.76 8.17
4.38 12.63 6.95
4.73 13.93 5.57
4.12 11.64 9.37
4.39 12.57 8.42
4.74 13.83 6.85
4.75 13.73 8.10
11.50 11.50 4.43 10.80 10.80 4.76 10.27 10.27 4.96
4.84 13.64 9.48
4.47 12.70 8.83
4.73 13.64 7.50
5.11 15.05 6.02
4.75 13.57 9.09
5.13 14.94 7.39
5.14 14.82 8.75
112
40°C
IPT
TC
SHC
IPT
kW
kW
kW
kW
4.50 10.88 7.83
4.93 10.24 7.58
4.77 11.78 6.71
5.23 11.18 6.60
5.15 13.04 5.48
5.65 12.42 5.46
4.49 10.80 9.02
4.90 10.19 8.71
4.78 11.70 8.13
5.22 11.09 7.93
5.16 12.88 6.63
5.64 12.30 6.58
4.79 11.63 9.42
5.21 11.00 9.13
5.17 12.75 7.78
5.62 12.19 7.68
5.21 12.77 9.19
5.60 12.18 9.01
4.86 11.75 8.46
5.34 11.06 8.18
5.16 12.72 7.25
5.66 12.07 7.12
5.57 14.08 5.91
6.11 13.41 5.90
5.30 11.00 9.41
5.17 12.64 8.78
5.64 11.98 8.56
5.58 13.91 7.17
6.09 13.29 7.11
5.59 13.77 8.40
6.08 13.16 8.29
6.05 13.15 9.73
43°C
TC
SHC
IPT
kW
kW
kW
5.23
5.54
5.99
5.20
5.53
5.97
5.52
5.96
5.83
5.66
6.00
6.48
5.62
5.98
6.46
5.97
6.44
6.31

Hide quick links: