CLEAN WASTE PUMP-OUT PUMP: (If so equipped)
Build-up of fine silt inside the optional Waste Pump can clog the pump even if the pump is not used, so this
maintenance procedure should be performed regardless of whether the Waste Pump has been used.
• After cleaning out the recovery tank, remove the cap and connect
the Pump-Out hose to the Waste Pump outlet fitting on the back of
the machine; run the hose to a drain.
• Remove the waste pump filter screen by turning it counterclockwise.
Remove the filter screen. Examine the screen and clean or replace as
needed.
• Re-install the filter screen. Thread the filter loosely on to the nipple
– Leave slightly loose to keep it easier to remove for future cleaning.
• Use a hose to fill the recovery tank approximately 1/2 full with
clean water.
• With Cord #1 plugged in, turn the Waste Pump switch to the ON
position.
• Let the pump run until it pumps the level down to the point below
the pump intake filter.
• Unplug the cord and turn the Waste Pump switch OFF.
• Open the drain valve and drain out the remaining water.
• Close the drain valve, replace the recovery tank lid, and dispose of the dirty water and debris.
FLUSH SOLUTION TANK AND PUMP:
• Pour two or three gallons of clean water into the solution tank.
• With Cords #1 & #2 plugged in, connect the pump prime hose to
the solution outlet female quick connect.
• Direct the end of the pump priming hose into the recovery tank
vacuum barb.
• Turn one or both of the vacuums ON and turn the solution pump
ON.
• Let the pump run until most of the water has been pumped out of
the solution tank.
Do not let the pump run dry. Turn the pump
OFF before the water gets to the bottom of the tank.
• Turn the vacuums OFF and disconnect the prime hose.
• Place a bucket under the drain valve; open the drain valve to drain
the water out of the recovery tank.
• Close the drain valve and dispose of the water.
If there is a heavy chemical build-up in the machine, hoses, or tools, a mild acid can be added to the rinse
water in the previous procedure (REFER TO PHOTOS ON FOLLOWING PAGE.)
• After the pump has been primed, turn the solution pump switch OFF and turn the vacuums OFF.
• Remove the pump priming hose and connect the solution hose and tools.
• Turn the solution pump ON and direct the tool spray into a bucket. Let the pump run until most of
the water has been pumped out of the solution tank.
Do not let the pump run dry.
Turn the pump OFF before the water gets to the bottom of the tank.