9.

TROUBLESHOOTING

PROBLEM
Alarm is On
All manuals and user guides at all-guides.com
REASON
Display shows . Device
has a short circuit or
demands too much surge
power.
Display shows . 12-volt
battery is too low.
Display shows voltage in
between 10.5 and 11.0-volts.
Display shows . 12-volt
voltage is too high.
Display shows .Device
demands more than the
inverter's continuous power
rating.
Display shows . Inverter
is too hot.
• 14 •
SOLUTION
Cycle the inverter power OFF
and ON.
If problem persists, use a
larger inverter or a smaller
device.
Remove the defective device.
See warranty and call
Customer Service 1-800-621-
5485 (Hours 7:00 am to 5:00
pm CST).
Recharge/replace battery
12-volt battery is low.
Recharge/replace battery.
The inverter will automatically
shut off after battery voltage
reaches 10.5-volts.
If in a vehicle, repair/replace
the alternator or charging
system.
Use a properly sized and
rated 12-volt battery.
If the input voltage returns to
15-volts or less, the inverter
will automatically restart.
Cycle the inverter power OFF
and ON.
If problem persists, use a
larger inverter or a smaller
device.
Increase the ventilation to the
inverter.
Move the inverter to a cooler
area.
Reduce the power
consumption of the device.
The inverter will automatically
reset after cooling.