Advertisement

Quick Links

Technical Guide
PCA 4000
The PCA 4000 Parts Curing Apparatus is the ideal solution for
post-curing parts that have been 3D printed using cDLM or DLP
technologies. The PCA 4000 utilizes a unique system of UV LED
light sources that use both 365 nm to deep cure and 405 nm for the
perfect surface cure of each part. It has a microprocessor-controlled
touchscreen interface and intuitive software that allows you to control
every aspect of the post-processing 3D printed models. With 360°
irradiation and controlled heating, the PCA 4000 can optimize your
productivity.
Applicable Printers: All cDLM and DLP printer series
Fig. 1
PCA 4000 FRONT VIEW
Cooling
ducts
Touch
screen
PCA 4000 CURING CHAMBER
Fig. 2
LED light source
Cooling
ducts
Touch
screen

Technical Specs

External dimensions: 14.33 x 15.9 x 12.55 in (364 x 404 x 319 mm)
Curing chamber dimensions: 7.87 x 7.87 x 7.48in (200 x 200x190mm)
Emitter type and quantity: 60 Hi-power LED 5 W
Irradiance system: OmniRay 360° Irradiance
Wavelengths: 365 nm - 405 nm
Emission opening: +/- 20 nm
Total emitter power: 150 W
System: Eco-passive
Heating control: 6x PID controller
Management: 16 bit IDM processor
Interface: 3.2 in TFT touch screen
Programs: 2 standard - customer set n°7 memory
Command: Auto off
Connectivity: 2.4 Ghz WIFI
Power supply: Internal
Power supply voltage: 110-230V 6-4A 50-60Hz

Environmental Conditions

Curing
Situate the PCA 4000 in a ventilated area away from sources of heat
chamber lid
and away from flammable materials and liquids that may cause a
safety risk - see Safety Instructions p. 4.
Keep the PCA 4000 at least 8 inches / 20 cm from the wall. To avoid
damaging the apparatus, do not obstruct in any way the cooling
ducts, their openings to the outside, the fans on the rear panel,
and fan on the base of the PCA 4000. Keep the PCA 4000 in an
environment with temperatures within 65° to 82° F / 18° to 28° C.

Recommended Custom Curing Times

Below is a list of recommended curing times for EnvisionTEC materials
Fan output
in the PCA 4000 curing apparatus. Curing times are subject to change.
(not pictured)
Material
Easy Cast 2.0
EC-3000
EC-500
E-3172
Curing chamber lid
E-3172
E-3843
E-3860
E-5015
E-AquaModel
Curing chamber
E-Guard 2.0
E-Guide 2.0
E-IND147
E-IND402
(Black, Gray)
Cooling
E-IND406
ducts
E-Model
(Light, Beige, HS)
E-Orthoshape
E-Partial
E-Rigid Form
(Charcoal, Amber)
E-Rigid PU
NextDent Gingiva Mask
© EnvisionTEC Page 1 of 4
TS-OPI-PCA-4000-V20210311-FN-EN.pdf
Time (H:MM:SS) Temp.
0:30:00
0:10:00
0:30:00
First cycle: 0:06:00
Second cycle: 0:30:00
0:01:00
First cycle: 0:06:00
Second cycle: 0:30:00
First cycle: 0:06:00
Second cycle: 0:30:00
0:20:00
0:02:00
0:01:00
0:01:00
First cycle: 1:30:00
Second cycle: 3:00:00
1:30:00
First cycle: 1:00:00
Second cycle: 2:00:00
0:01:00
0:01:00
0:04:00
0:04:00
0:05:00
0:02:00
Power
60˚ C
100%
60˚ C
100%
60˚ C
100%
60˚ C
100%
60˚ C
100%
60˚ C
39%
60˚ C
100%
60˚ C
100%
60˚ C
68%
160˚ C
100%
60˚ C
100%
20˚ C
100%
20˚ C
35%
20˚ C
35%
60˚ C
68%
170˚ C
100%
60˚ C
100%
60˚ C
100%
140˚ C
100%
20˚ C
100%
20˚ C
100%
20˚ C
100%
20˚ C
100%
60˚ C
100%
20˚ C
100%

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PCA 4000 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Envisiontec PCA 4000

  • Page 1 - see Safety Instructions p. 4. Keep the PCA 4000 at least 8 inches / 20 cm from the wall. To avoid damaging the apparatus, do not obstruct in any way the cooling...
  • Page 2 The PCA 4000 will display a brief start-up screen and will then go to stand-by mode. In this mode the PCA 4000 is ready to start the required program. It is connected to power, but does not emit UV rays while in stand-by mode - see Safety Instructions p.
  • Page 3 2 From the Custom Program list, choose the number of the program to edit from Prg 1 - Prg 8 The PCA 4000 system has two post curing program options - Custom 3 The custom program screen will open, ex. Program 1 Fig. 10.
  • Page 4 Prog: 5 100% 100% 30°C 30°C 00:10:00 00:10:00 BASIC BASIC PCA 4000 if it will not be used for an extended period of system and respective accessories. The obligation of EnvisionTEC 00:00 Prog: 2 100% 30°C 00:10:00 Connected 100% Prog: 3 30°C...

Table of Contents