[11] RS232C Test (Port Test, Batch Test)
[Function]
Tests the communication of RS232C using the loop back tool.
[IMPORTANT]
Information of the loop back tool.
Pin assignment on the register side (male)
1
6
[11-1] RS232C Port Test
[Operation]
Connect the loop back tool to the connector which you wish to test.
n 0 4 d k
Command : x
x: Baud rate selection (bps)
0=2400, 1=4800, 2=9600, 3=19.2 k, 4=38.4 k, 5=56 k, 6=Invalid, 7=115.2k
n: Number of times to run
0
Once (Can be omitted)
1 ~ 9
Infi nite loop (To forcibly terminate the test, press the
d: COM Port select
1
COM1 (UART1)
2
COM2 (UART0)
[Display of the Result]
- - >
TxD
[Printout of the Result]
COM1
RTS1=1 -- > CTS1=1
DTR1=1 -- > DSR1=1
RTS1=0 -- > CTS1=0
DTR1=0 -- > DSR1=0
-- > RxD
TxD
END
SE-S400/SE-S800/PCR-T500/PCR-T520/SE-C450
SE-S3000/SE-S900/PCR-T2300/PCR-T2400/SE-C3500
Pin
5
9
RxD
OK
30041
OK
OK
OK
OK
OK
30041
– 31 –
Signal Name
1
DCD
2
RxD
3
TxD
4
DTR
5
GND
6
DSR
7
RTS
8
CTS
9
RI