Electronic Function; Abbreviation; Display Function - Fisher FSAIF-Pro-95AE2 Service Manual

Split wall-mounted type
Table of Contents

Advertisement

8. Electronic function

8.1 Abbreviation

T1: Indoor room temperature
T2: Coil temperature of evaporator
T3: Coil temperature of condenser
T4: Outdoor ambient temperature
Tp: Compressor discharge temperature

8.2 Display function

8.2.1 Icon explanation on indoor display board.
Digital display:
Displays the temperature settings when the air
conditioner is operational.
Displays the room temperature in FAN mode.
Displays the self-diagnostic codes.
Dispalys '
' for three seconds when Timer
ON, Fresh, Swing, Turbo or Silence feature is
activated.
Dispalys '
' for three seconds when Fresh,
Swing, Turbo or Silence feature is cancelled.
Dispalys '
' under deforsting operation.
Dispalys '
' when anti-cold air feature is
activated under heating mode.
Dispalys '
' during self clean operation (if
aplicable).
Dispalys '
' under 8℃ heating operation (if
aplicable).
When ECO function(optional) is actived,the
"
" illuminates gradually one by one as
In one second interval.
NOTE:
A guide on using the infrared remote is not
included in this literature package.