Danfoss VLT HVAC Drive FC 131 Operating Manual page 38

Hide thumbs Also See for VLT HVAC Drive FC 131:
Table of Contents

Advertisement

VLT® HVAC Drive FC 131
Operating Guide
Parameter
Option/range
Parameter 1-20
0.18–110 kW/0.25–150 hp
Motor Power
50–1000 V
Parameter 1-22
Motor Voltage
20–400 Hz
Parameter 1-23
Motor Frequen-
cy
Parameter 1-24
0.01–10000.00 A
Motor Current
Parameter 1-25
50–9999 RPM
Motor Nominal
Speed
0.1–1000.0 Nm
Parameter 1-26
Motor Cont.
Rated Torque
0–99.990 Ω
Parameter 1-30
Stator Resist-
ance (Rs)
Parameter 1-37
0.000–1000.000 mH
d-axis Induc-
tance (Ld)
38 | Danfoss A/S © 2021.06
Default
Usage
Parameter 1-66 Min. Current at Low Speed.
Parameter 1-70 PM Start Mode.
Parameter 1-72 Start Function.
Parameter 1-73 Flying Start.
Parameter 1-80 Function at Stop.
Parameter 1-82 Min Speed for Function at Stop [Hz].
Parameter 1-90 Motor Thermal Protection.
Parameter 2-00 DC Hold/Motor Preheat Current.
Parameter 2-01 DC Brake Current.
Parameter 2-02 DC Braking Time.
Parameter 2-04 DC Brake Cut In Speed.
Parameter 2-10 Brake Function.
Parameter 4-14 Motor Speed High Limit [Hz].
Parameter 4-19 Max Output Frequency.
Parameter 4-58 Missing Motor Phase Function.
Parameter 14-65 Speed Derate Dead Time Compensation.
Size related
Enter the motor power from the nameplate data.
Size related
Enter the motor voltage from the nameplate data.
Size related
Enter the motor frequency from the nameplate data.
Size related
Enter the motor current from the nameplate data.
Size related
Enter the motor nominal speed from the nameplate data.
Size related
This parameter is available when parameter 1-10 Motor Con-
struction is set to options that enable permanent motor
mode.
Changing this parameter affects the settings of other pa-
rameters.
Size related
Set the stator resistance value.
Size related
Enter the value of the d-axis inductance. Obtain the value
from the permanent magnet motor datasheet.
Programming
N O T I C E
AQ367426199594en-000101 / 130R0988

Hide quick links:

Advertisement

Table of Contents
loading